4. CONTROLS
Button Led
L
-
-
T1
Fixed
Flashing
T2
Fixed
Flashing
T3
Fixed
-
T4
Flashing
-
S1
Fixed
Flashing
Function
Turns the lights ON/OFF at maximum strength.
Press and hold the button for approximately 5 seconds, with all the loads turned off (Motor
and Lights), to turn the Activated Charcoal Filter alarm on. The 4 LEDs on the buttons
flash twice to confirm.
To turn the alarm off, press the button again and hold for at least 5 seconds. The 4 LEDs
on the buttons flash once.
Turns the motor on/off at speed one.
24h function:
Press and hold the button for approx. 2 seconds to Activate/Deactivate the motor in 24h Air
Circulation mode, a speed that allows ducting for 10 minutes every hour, for a 24 hour cycle.
Cannot be activated if Intensive or Delay modes are active.
Turns the Motor on at speed two.
Delay function:
Press and hold the button for approx. 3 seconds to Activate/Deactivate the Delay function
(automatic switching off of the Motor, the Fans and the Lighting with a 30' delay).
Cannot be enabled when Intensive or 24h are on.
Turns the Motor on at speed three.
Press and hold the button for approximately 3 seconds, with all the loads turned off (Motor
and Lights), to reset the Filter saturation alarm. The LED S1 flashes three times.
Turns the Motor on at Intensive.
Speed.This speed is timed to run for 6 minutes. At the end of this time, the system returns
automatically to the speed that was set before. If it is activated with the motor turned off,
the hood will switch to OFF at the end of the time.
Press and hold for 5 seconds to enable the remote control, indicated by the LED flashing twice.
Press and hold for 5 seconds to disable the remote control, indicated by the LED flashing
just once.
Signals the Metal Grease Filter saturation alarm, indicating that it is necessary to wash the
filters. The alarm is triggered after the Hood has been in operation for 100 working hours.
When this is activated, it signals the Activated Charcoal Filter saturation alarm, indicating
that the filter must be changed; the Metal Grease Filters must also be washed. The
Activated Charcoal Filter saturation alarm comes into operation after the Hood has been
working for 200 hours.