level Switch
Level switch is used to tell if the level of coolant in the tank drops below certain level. When the level of the cool-
ant drops below level switch position in the tank, control board reads the switch open signal, an error signal is
PROPRIETARY AND CONFIDENTIAL
sent to CNC/Process controller by the power supply through CAN communication.
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY
OF ESAB WELDING & CUTTING. ANY REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN PERMISSION OF ESAB WELDING & CUTTING
IS PROHIBITED.
VENDOR:
VENDOR P/N:
Coolant Filter
A filter is used to prevent the foreign particles entering the power source through coolant and damaging the
equipment.
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL .03
ANGULAR: MACH .1 BEND .5
TWO PLACE DECIMAL
THREE PLACE DECIMAL
MATERIAL
FINISH
DATE
APPROVED
DO NOT SCALE DRAWING
FLOAT SG:
MAX PRESSURE: 100PSIG
LEADS:
MADISON COMPANY
M8790
NAME
DRAWN
MEA
PMD
CHECKED
.015
ENG APPR.
MEA
.005
COMMENTS:
0.60
22GA, 24INCHES
Maintenance
(8)0558011991
DESCRIPTION:
PLASTIC SIDE-MOUNTED SWITCH
STEM:
FLOAT:
MAX TEMP:
NOM CURRENT: 30VA SPST SWITCH
FLOAT SG:
MAX PRESSURE: 100PSIG
LEADS:
PA6900-11-16
DATE
11/14/12
SWITCH LEVEL
11/14/12
11/15/12
BULKHEAD
SIZE
DWG. NO.
A
(8)0558011991
SCALE:1:5
WEIGHT:
DIMENSIONS ARE IN INCHES
POLYPROPYLENE
POLYPROPYLENE
105C
0.60
22GA, 24INCHES
10/20/11
REV.
-+
SHEET 1 OF 1
PA6900-11-16
NAME
DATE
411 S. Ebenez
Florence, SC
43
10/2