1 - Description of the unit
The ANDROMEDA range of display units are built in modules with a useful internal length of 2020 mm (MODEL 210) and
2420 mm (MODEL 250). They are equipped with an integral condensing unit, with fan assisted refrigeration. FIG. 1
clearly shows the general look and dimensions of these units.
2 - Handling the unit
The unit comes with wooden crating allowing handling by a forklift truck. Only authorised technicians should handle the
unit.
FIG. 2 shows the weight of the units in their various lengths and their lifting points.
3 - Receipt and storage
On delivery, check that the unit hasn't been damaged during transit. Check the condition of the packaging: if the
packaging is damaged, check the contents in the presence of the carrier.
For storage, make sure that the unit is protected against the atmospheric agents and stored at a temperature between -
25°C and +55°C; 30-95% relative humidity.
Take special care when unpacking the unit, as the packaging contains various parts and/or accessories needed to
complete the display unit (Grilles, Price Indicators, Dividers, etc.).
Remove the wooden crating (see FIG. 4) and then remove the transparent protection around the unit.
Place the display unit exactly where you want to install it. Move the unit properly: never drag by its handles!
Warning: Inform the Manufacturer immediately if the goods arrive damaged: any delay in doing so relieves the
Manufacturer of all liability.
Any damage to the cabinet occurring during shipment and storage may not be attributed to the manufacturer.
4 - Installation and environmental conditions
The unit must sit on a perfectly leveled floor. When fully loaded, the display unit should not vibrate (see FIG. 5). The
efficiency of the unit may be compromised if this isn't perfectly leveled!
The display unit must never be placed in areas where explosive gas substances are used.
The unit should not be left outdoors or exposed to the rain (see FIG. 3).
The performance of the cabinet refers (according to the international standard EN ISO 23953-1/2) to environmental
climatic class 3 which consists of a room temperature of 25°C with relative humidity of 60%.
Sufficient space must be provided to guarantee good air circulation for the condenser (see FIG. 10). Do not place objects
in front of the condenser protection grid, as this could compromise the efficiency of the refrigerated display unit (see
FIG.6). The performance will be less than expected if the environmental conditions differ from those foreseen, or the
display units are exposed to air flows of more than 0.2m/sec or heat radiation.
To get around this problem, the User should send the Manufacturer details of the environmental conditions before
finalising the design of the units, so that the technical parameters and material options can be modified and the installer
be informed of the refrigerating power actually required.
5 - Assembly of cabinet
The operations of assembly of the cabinet should be carried out exclusively by authorized personnel.
Each frame must be anchored to the wall (minimum wall thickness 100 mm, concrete compressive strength 25 N/mm2)
using 6 toggles M8 (characteristics recommended for the toggles: tensile strength 4 kN, shear strength 4 Kn
1. Place the bearing frame, level it (FIG. 7 ref. 1) and anchor it to the wall (FIG. 7 ref.2).
2. Place the bench on the bearing frame, anchor it to the wall (FIG. 7 ref. 3) and fasten it to the frame using the screws
provided (FIG. 7 ref.4).
3. Place the bottom cover (FIG. 7 ref. 5) and secure it using the dedicated mount (FIG. 7 ref. 6).
4. Place the self-evaporating drip tray of condensate water (FIG. 7 ref.7).
The internal and the external surfaces of the cabinet are covered with a protective film that must be removed before
commissioning of the equipment.
6 - Electrical connections
Important: installation should be made following the manufacturer's instructions, by qualified personnel only, in conformity
with the electric safety regulations in force. Please refer to the electrical diagram on FIG.15-16.
At the input of the supply it is necessary to install an omni-polar magnetothermic/differential device with contact opening
equal to 3 mm and adequate cut-off power.
Warning: Before connecting the unit to the mains, make sure that the mains voltage corresponds to that indicated on the
serial plate (bearing in mind that the max acceptable variations in voltage are +/-10%). Check that the cable used has the
right cross-section and length to withstand the current and the power absorbed by the combination, as indicated in TAB.1.