Télécharger Imprimer la page

Velleman PIR415 Mode D'emploi page 5

Masquer les pouces Voir aussi pour PIR415:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
light sensitivity
movement sensitivity
5"
on-time
30"
on time
1'
on-time
3'
on-time
5'
on-time
8'
on-time
Note: Only the highest selected on-time will be applicable.
7. Connect the wiring [1] to the terminals according to the diagram
on page 2.
Warning: Do not short-circuit any terminals.
8. Reinstall the fuse of the electric circuit and switch it on.
9. To test the PIR sensor, set the light sensitivity to OFF and the
movement sensitivity and 5" to ON. The load should switch on
immediately and – when no movement is detected – switch off
after 5 s.
Caution: DO NOT change the DIP switch settings when power is
connected.
5.
Technical Specifications
switch type
detection angle
detection range
rated load
power supply
working temperature -10 °C to +40 °C
working humidity
time-delay switch
light control
dimensions
weight
Use this device with original accessories only. Velleman nv cannot be
held responsible in the event of damage or injury resulting from
(incorrect) use of this device. For more info concerning this product
and the latest version of this manual, please visit our website
V. 07 – 11/06/2018
PIR415
relay
100°
8 m (@ 22 °C)
max. 800 W (tungsten - max. 3.3 A) / 200 W
(fluorescent max. 1.25 A)
220-240 V~, 50 Hz, µ 1
< 93 % RH
5 s, 30 s, 1 min, 3 min, 5 min, 8 min
< 3 lx to 2000 lx
visible part
hidden part (controller) 55 x 25 x 35 mm
± 41 g
5
ON
< 10 lx
low
5 seconds
30 seconds
1 minute
3 minutes
5 minutes
8 minutes
E
4
Ø 22 x 10 mm
OFF
always
high
-
-
-
-
-
-
©Velleman nv

Publicité

loading