NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
To start generator the first time:
Add engine lubricant per the Operator's Manual
instructions.
Place the Easy Start dial to the COLD START (CHOKE)
position.
Fill the fuel tank per the Operator's Manual instructions.
Pull the recoil starter until the engine starts.
Allow the engine to run for 15-30 seconds, then move
the Easy Start dial to the RUN/RE-START position.
To start subsequent times:
Unplug all loads from the generator.
Turn the Easy Start dial to the COLD START position.
NOTE: When the Easy Start dial is in the COLD START
(top) position, the fuel will flow from the fuel tank to the
engine. If engine is warm, turn the Easy Start dial to the
RUN/RE-START (middle) position.
Pull the recoil starter until the engine runs.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place. Initial starting of the
unit may require additional pulls.
Allow the engine to run for 15-30 seconds, then move
the Easy Start dial to the RUN/RE-START position.
STOPPING THE ENGINE
See Figures 5 - 6.
Remove any load from the generator.
Place the Easy Start dial in the OFF/STORAGE position.
To stop the engine in an emergency situation:
Place the Easy Start dial in the OFF/STORAGE position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
OPERATION
PAIRING THE BLUETOOTH
See Figure 8.
Installing the RYOBI GENCONTROL app on your Bluetooth
enabled iOS or Android device allows you to view and control
many of the generator's functions from your device.
From the app store on your iOS or Android Bluetooth
enabled device, locate and install the RYOBI
GENCONTROL™ app.
Open the app and follow the directions as shown in the
GENControl app.
NOTE: Make sure Bluetooth
Start the generator. Push and hold the "Push and Hold to
Pair" button below the LCD panel on the generator until
the LCD panel displays "Pairing Mode."
The LCD screen on the generator and the app on your
device will indicate a successful pairing.
NOTE: If the generator and app do not pair, make sure
that "Pairing Mode" is displayed during the pairing process
and that Bluetooth
Press the menu icon in the top left corner of the screen.
This will show you the available features that can be
controlled through the app.
MOVING THE GENERATOR
See Figure 9.
Place the Easy Start dial in the OFF/STORAGE position. In
the OFF/STORAGE position, the fuel valve will be closed
and prevent any gas flow.
Allow 30 minutes of "cool down" time before storing the
machine. Make sure engine and exhaust of unit are cool.
Pull the retractable handle out or carry by the carry handles.
Facing the front of the generator, grasp the folding handle
firmly with one hand.
Lift the generator toward you until it balances on the
wheels.
Turn around and pull the unit along behind you to the
desired location.
Lower the generator until it sits securely on a flat surface.
MAINTENANCE
WARNING:
Before inspecting, cleaning or servicing the machine,
shut off engine, wait for all moving parts to stop, and
disconnect spark plug wire and move it away from
spark plug. Allow 30 minutes of cool down time before
performing any maintenance. Failure to follow these
instructions can result in serious personal injury or
property damage.
14 — English
GENERATOR
®
is enabled on your device.
®
is enabled on your device.
®
®
®