WARNING:
NEVER ignore an automatic shutoff event. IF AUTOMATIC
SHUTOFF OCCURS – YOU MUST leave the area imme-
diately and relocate to an open outdoor area. Ventilate
the area thoroughly before occupying again. Ensure the
generator is located in an open, outdoor area at least 20
feet away from all doors, windows, and occupied spaces.
Always point exhaust away from occupied structures.
Never run the generator in enclosed areas (e.g. not in a
house or garage). Failure to follow these instructions can
lead to carbon monoxide (CO) poisoning which can result
in death or serious personal injury.
WARNING:
If this generator will be used only with cord and plug-
connected equipment, National Electric Code does
not require that the unit be grounded. However, other
methods of using the generator may require grounding
to reduce the risk of shock or electrocution. Consult a
qualified electrician, electrical inspector, or local agency
having jurisdiction for local codes or ordinances to find
out if grounding is needed in your situation before using
the generator.
WARNING:
Do not allow familiarity with this product to make you
careless. Remember that a careless fraction of a second
is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and
local fire prevention regulations. Check with appropriate
authorities. Contact customer service or a qualified
service center to purchase a replacement spark arrestor.
NOTICE:
Before each use, inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualified service center for assistance.
OPERATION
APPLICATIONS
This generator is designed to supply electrical power for
operating compatible electrical lighting, appliances, tools,
and motor loads.
BEFORE OPERATING THE UNIT
Only use OUTSIDE and at least 20 feet away from
windows, doors, and vents as recommended by the U.S
Department of Health and Human Services Centers for
Disease Control and Prevention. Your specific home and/
or wind conditions may require additional distance.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Always position the generator on a flat firm surface.
SPECIAL REQUIREMENTS:
There may be General or State Occupational Safety and
Health Administration (OSHA) regulations, local codes or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
In some areas, generators are required to be registered
with local utility companies.
If the generator is used at a construction site, there may
be additional regulations which must be observed.
USB CHARGING PORTS
See Figure 1.
The USB-dedicated charging ports will charge most USB-
compatible devices.
For MP3, cell phones, and other small USB devices (up
to 1.9 Amps), connect to the top USB port.
For tablets and high-charging current devices (up to
2.1 Amps) connect to the bottom USB port.
NOTE: The USB-dedicated charging port provides power
only; it does not provide any communication capabilities. A
suitable USB cable must be provided by the user.
GENCONTROL™ LCD DISPLAY
See Figure 2.
NOTE: The LCD display will not work unless the unit is
running.
Fuel level: The fuel level indicator will show how much fuel
is remaining.
Load level: The load level indicator will show the connected
load. If the generator is approaching the maximum wattage/
amperage capacity, the indicator will blink. If load level capacity
is exceeded, the LCD display will show OVERLOAD. To reset
the generator, remove all loads from the generator and press
the reset button (see fig. 1). Add loads back to the generator
one at a time being careful not to exceed the generators watt-
age rating.
Run time: The LCD display will show the approximate re-
maining run time based on fuel level and load.
Auto idle: The LCD display will show if the idle is on or off.
12 — English