aintenance and cleaning
For safety reasons before carrying out any maintenance or cleaning operation,
turn off the unit and cut the voltage by turning the line switch to OFF.
Maintenance
The maintenance operations for the FWP air conditioner and hot-air heating units
are limited to the periodic cleaning of the air filter and the heat exchanger, and the
checking of the working efficiency of the condensate discharge.
Only skilled personnel may perform the maintenance.
Pay utmost attention during the maintenance operations: accidentally coming into
contact with some of the metallic parts might cause injuries, therefore use safety
work gloves.
Every time the units are started after a long idle period, make sure that air is NOT
present in the heat exchanger.
The motor is maintenance-free since it is equipped with self-lubricating bearings.
Cleaning the air filter
Cut voltage to the unit by turning the line switch to OFF.
For cleaning the air filter proceed as follows:
Access the equipment through the inspection panel and remove the air filter
as shown in figure 7 by unscrewing the fixing knobs.
Wash the filter with lukewarm water or, for dry powders, with compressed
air.
Reassemble the filter after having it dried up.
Cleaning the heat exchanger
It is advisable to check the condition of the heat exchanger before the start of the
summer season. Also check if the fins are not clogged by impurities.
To access the heat exchanger, remove the delivery panel and the condensate tank.
Upon having accessed the heat exchanger, clean with compressed air or low
pressure steam, without damaging the fins of the heat exchanger.
Before operating it in the summer, check the condensate discharges regularly.
d
isposal reqUirements
NOTE
Adequate and regular maintenance and cleaning means energy
conservation and cost saving.
Dismantling of the unit should be done in accordance with the relevant local and
national legislation.
t
roUBleshooting
If the unit does not work properly first check the points reported in the table below
before requesting service.
If the problem cannot be solved contact your dealer or service centre.
Symptom 1: The unit does not run at all
P
ossible causes
Power failure
The automatic circuit breaker tripped
The switch is on STOP ("O") position
Symptom 2: Poor cooling or heating performance
P
ossible causes
Dirty or clogged air filter
Obstacle near the air inlet or outlet
Air inside the heat exchanger
FWP
Ducted fan coil units
UT66002382
c
orrective action
Restore power
Contact service centre
Turn ON the unit, select "I"
c
orrective action
Clean the air filter
Remove the obstacle
Contact the installer
P
ossible causes
Doors and windows are open
The unit is running at low speed
Symptom 3: The unit leaks
P
ossible causes
The unit is not installed with the correct incli-
nation
The condensate discharge is clogged
Units are marked with the following symbol:
This means that electrical and electronic products may not be mixed with
unsorted household waste. Do NOT try to dismantle the system yourself: the
dismantling of the system, treatment of the refrigerant, of oil and of other parts
must be done by an authorized installer and must comply with applicable
legislation. Units must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed of correctly, you will
help to prevent potential negative consequences for the environment and human
health. For more information, contact your installer or local authority.
c
orrective action
Close doors and windows
Select medium or high fan speed
c
orrective action
Contact the installer
Contact the installer