8.2 CONNECTING THE DC POWER
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and
local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated,
grounded circuit which is protected by a properly sized circuit breaker. The proper voltage, frequency and
amperage are listed in this manual, and on the product rating plate on the back of the toilet.
NB!
Power requirements
Power consumption
•
The electrical installation and repairs may only be performed by a specialist in accordance with the
applicable regulations and national standards.
•
The respective negative and positive cables of the DC connection may not be joined with one another in a
camper. This can cause electrical interference and damage to electrical components.
•
When connecting the toilet to the mains DC power take the following into consideration:
•
Make sure the cable has sufficient current rating for the expected load in the circuit, including
a margin of safety.
•
Make sure the cable cross section is dimensioned for the intended cable run length, and that the
cable will not cause the voltage to drop.
NOTE!
•
The device plug must be easily accessible so that you can unplug it if required, thereby disconnecting the
toilet from the power.
•
The connection cable must be laid so that it does not come in contact with sharp edges.
•
Changes to the internal electrical installation or the connection cable must be performed by a professional
tradesman or a similarly qualified person in order to prevent safety hazards.
•
It may be necessary to protect the receptacle with a GFCI. Ensure that all installations are in accordance with
national electrical code.
PCB CONNECTOR OVERVIEW
12V/PROPANE GAS NA 1.0
C
M
FAN BLOWER +
FAN BLOWER-
Y
MOTOR +
MOTOR -
CM
UPPER MICROSWITCH + RED,
MY
UPPER MICROSWITCH - GREY,
LOWER SWITCH +
CY
LOWER MICROSWITCH - WHITE,
ASHCONTAINER +
CMY
ASHCONTAINER-
TOILET LID +
K
TOILET LID -
TEMPERATURE SENSOR - WHITE
TEMPERATURE SENSOR+WHITE/GREEN STRIPES
12
Input
12V DC (11-14,4V)
Standby
0,005 Amp
PCB_Connection_GAS_NA_1_0_2019_124x64mm.pdf 1 22.05.2019 14:06:11
RED,
BLUE CRIMP
BLUE,
BLUE CRIMP
RED,
RED CRIMP
BLACK,
RED CRIMP
RED CRIMP
RED CRIMP
YELLOW, YELLOW CRIMP
YELLOW CRIMP
BLACK,
BLUE CRIMP
BLACK,
BLUE CRIMP
BLACK,
WHITE CRIMP
BLACK,
WHITE CRIMP
GROUND
IGNITION BOX
12V
BURNER FAN
DISPLAY
CABLE
Current
4 Amp
Incinerating
1,3 Amp
GROUND
DISPLAY
CONTROL PANEL
PROGRAM
SIGNAL CABLE
THERMAL
SWITCH
GAS VALVE