POWER SOURCE

This saw is equipped with a
120-volt, 60-HZ alternating current. See instructions below
regarding proper connections for your saw. For voltage,
the wiring in a shop is as important as the motor's rating.
A line intended only for lights may not be able to properly
carry the current needed for a power tool motor; wire that
is heavy enough for a short distance may be too light for
a greater distance; and a line that can support one power
tool may not be able to support two or three.
DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

EXTENSION CORDS

Never use a damaged extension cord.
Check extension cords before each use. If damaged,
replace immediately. Touching the damaged area could
cause electrical shock resulting in serious injury.
Keep the extension cord clear of the
work area. Position the cord so it will not get caught on
lumber, tools or other obstructions.
• Use the "MINIMUM GAUGE EXTENSION CORD" table,
show on the right, to determine the proper length and
gauge for any extension cord used to supply power to
your tool.
Use properly rated extension cords. When using an
extension cord, be sure to use one heavy enough to carry
the current required by your machine. An undersized
cord will cause a drop in line voltage, resulting in loss of
power and overheating. The table shows the minimum
gauge to use depending on the cord length. If in doubt,
use the next heavier gauge. The smaller the gauge
number, the heavier the cord. Only round, jacketed
cords listed by Underwriter's Laboratories (UL) should
be used.
When working outdoors, use an extension cord
designed for outdoor use.

POWER CONNECTIONS

15-amp motor
for use with a
Save These Instructions.
Refer to them often and use them to instruct others.
If tool is loaned to someone, also loan them these instructions.
A separate electrical circuit should be used for your
machines. This circuit should not be less than #12 wire and
should be protected with a 20-amp time lag fuse. Before
connecting the machine to the power line, make sure the
switch is in the "OFF" position and be sure that the electric
current is of the same characteristics as indicated on the
machine. A substantial voltage drop will cause a loss of
power and overheat the motor. It may also damage the
machine.
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH
STATIONARY ELECTRIC MACHINES
AMPERE
VOLTS
RATING
0-6
120
0-6
120
0-6
120
0-6
120
6-10
120
6-10
120
6-10
120
6-10
120
10-12
120
10-12
120
10-12
120
10-12
120
12-16
120
12-16
120
12-16
120
7
TOTAL
GAUGE OF
LENGTH OF
EXTENSION
CORD IN
CORD
FEET
Up to 25
18 AWG
25-50
16 AWG
50-100
16 AWG
100-150
14 AWG
Up to 25
18 AWG
25-50
16 AWG
50-100
14 AWG
100-150
12 AWG
Up to 25
16 AWG
25-50
16 AWG
50-100
14 AWG
100-150
12 AWG
Up to 25
14 AWG
25-50
12 AWG
GREATER THAN 50 FEET
NOT RECOMMENDED