1. Notice
The following data gives information on all mobile aluminium towers
and are compulsory.
Example: EN 1004 - 3 - 7,6 / 11,6
A x B
Platformlength x framewidth
2. General information
When in use outside or in open structures, at windspeeds of 12m/s
and more (windforce 6 on the Beaufort scale, noticable hinder when
walking), oncoming gales or at the end of each working day or shift
change, attention has to be paid to the following:
Dismantle aluminium tower, or move into a windsheltered area, or
secure it adequatly against tipping over or rolling away.
3. Erection and dismantling
ATTENTION: only persons familiar with these instructions are
allowed to erect, dismantle and use the aluminium tower.
For erecting and dismantling at least 2 persons are needed.
Before erecting the aluminium tower, ensure yourself if all parts, tools
and safety equipment are directly available on location.
Check following points before erecting:
- Aluminium towers shall only be used and only be moved manually
on firm, levelled surface which is free from obstacles; distribute loads
evenly, when necessary with planks or equivalent equipment.
- Windspeeds may not exceed 12m/s.
14
h1 max.
h1 max.
Max. platformheight outdoors
Safety instructions
Aluminium tower according EN 1004; Class 3; maximum height
outdoors 7,6m; maximum height indoors 11,6m.
h2 max.
Max. platformheight indoors
The aluminium tower can be levelled out by the spindles ( if attached).
The maximum deviation of the upright position may not be more than
1% level. The manufacturers instructions for the aluminium tower has
to be followed and should take place in given order.
Safety Legislation: Horizontal brace at 0,5m above each platform is
obligatory and therefore mentioned in the parts-list and the
instructions.
ATTENTION: Damaged or faulty parts may not be used. Only use
original parts from the manufacturer.
When erecting and dismantling the aluminium tower, platforms at
every 2 meter (trapdoor decks or scaffolding planks, dim.
3000x280x50mm) are to be used. When used outside or against a
wall, additional parts and/or ballast has to be used according to the
manufacturers instructions.
Before use, check that the tower has been erected correctly and
completely.
To erect the aluminium tower follow the pictures in the instructions.
Dismantling should take place in reverse order.
Max.
Max. load kg/sq. m
2016-05 0095535 6473