Troubleshooting
Malfunction
Cause
IS 240 DUO without power
Fuse has blown; not
y
switched on
y
Short-circuit
y
Twilight setting in night-
IS 240 DUO does
time mode during
not switch on
daytime operation
y
Bulb burned out
Power switch off
y
y
Fuse blown
y
Detection zone not
correctly adjusted
Continued movement
IS 240 DUO does
y
within the detection zone
not switch off
y
Switched on light is within
detection zone and swit-
ches on again as a result
of temperature change
y
Set to continuous
operation by indoor
series switch
y
Switched on light is
IS 240 DUO keeps
within detection zone
switching ON/OFF
Animals moving in
y
detection zone
y
Wind is moving trees
IS 240 DUO switches
and bushes in the
on when it should not
detection zone
Cars in the street
y
are detected
y
Sudden temperature
changes due to weather
(wind, rain, snow) or
exhaust air from fans or
open windows
18
Remedy
Replace fuse, switch on
y
mains switch, check
wiring with voltage tester
y
Check connections
y
Adjust setting
y
Replace light bulb
Switch on
y
y
Replace fuse, check
connection if necessary
y
Readjust
Check zone and readjust
y
if necessary or apply
shroud
y
Readjust zone or apply
shroud
y
Series switch to
automatic
y
Adjust detection zone or
apply shrouds, increase
distance
Adjust zone or apply
y
shrouds
y
Adjust zone or apply
shrouds
Adjust zone or apply
y
shrouds
y
Adjust detection zone or
install in a different place

Technical specifications

Dimensions (H x W x D):
Output:
Connection:
Angle of coverage:
Pivoting range of the sensor:
Reach:
Time setting:
Twilight setting:
Enclosure:
Declaration of conformity
This product complies with
the European Directive on
Low-Voltage Appliances,
73/23/EEC and the EMC
Directive 89/336/EEC.
Functional warranty
This STEINEL product has
This warranty shall not
been manufactured with
cover damage to wearing
great care, and its operation
parts or damage and faults
and safety have been tested
caused by incorrect opera-
in conformity with the current
tion or maintenance.
regulations. Production is
Breakage due to a fall is
also submitted to final
also not covered.
random-sample testing.
STEINEL undertakes the
Further consequential dam-
guarantee for perfect condi-
age to external items is
tion and function.
excluded.
The warranty period is 36
Claims under warranty shall
months, starting on the date
only be accepted if the
of sale to the user. We
product is sent fully assem-
undertake to remedy faults
bled and well packed com-
caused by material or manu-
plete with sales slip or
facturing defects. This war-
invoice (date of purchase
ranty undertaking shall be
and dealer's stamp) to the
performed by the repair or
appropriate Service Centre
replacement of the defective
or handed in to the dealer
parts, at our own discretion.
within the first 6 months.
90 x 60 x 100 mm
max. 1000 W (ohmic load, e.g. filament bulb)
max. 500 W (uncorrected, inductive,
cos ϕ = 0,5, e.g. fluorescent lamps)
max. 600 W (electronic ballasts, capacitive,
e.g. energy-saving lights, max. 8)
230–240 V, 50 Hz
h
h
240
(with 180
angle of aperture)
Fine adjustment ± 80°
max. 12 m (electronically stabilised)
10 sec. – 15 min.
2–2000 lux
IP 54