The ground is not level or not flat enough.
Noisy
The sound comes from the flowing of the
refrigerant inside the appliance.
E0 Code
Room temperature sensor failed.
E1 Code
Condenser temperature sensor failed.
E2 Code
Water tank full when cooling.
E3 Code
Evaporator temperature sensor failed.
TECHNICAL DATA
Notice: Operation temperature range:
Dry bulb temperature /
Wet bulb temperature(℃)
Below data for your operating reference
Model
Rated voltage
Rated frequency
Rated input
Rated current
Cooling capacity
Moisture removal (L/H)
Air flow
ERP INFORMATION
Trademark
Model identification
Sound power (cooling)
Name of refrigerant
Rated power input for cooling (kW)
Rated energy efficiency ratio
GWP (kgCO
eq)
2
Energy efficiency class
Energy consumption for double ducts
appliances (kWh/h)
Energy consumption for single duct
appliances (kWh/h)
Maximum cooling
Minimum cooling
35/24
18/12
PAC-122838.3
220-240V
50Hz
785W
3.5A
2050W
(7000Btu/h)
0.8
320m³ /h
Value
Emerio
PAC-122838.3
≦65dB(A)
R290 (0.14kg)
0.785
2.6
3
A
N.A
0.785
Place the appliance on a flat, level
surface if possible.
It is normal.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
Replace condenser temperature sensor.
Contact authorized service technician
for repair.
Take off the rubber stopper and empty
the water.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
PAC-122839.2
220-240V
50Hz
1000W
4.5A
2600W
(9000Btu/h)
1.0
320m³ /h
Value
Emerio
PAC-122839.2
≦65dB(A)
R290 (0.16kg)
1.0
2.6
3
A
N.A
1.0
- 10 -
PAC-120876.1
220-240V
50Hz
1230W
5.5A
3200W
(11000Btu/h)
1.1
320m³ /h
Value
Emerio
PAC-120876.1
≦65dB(A)
R290 (0.16kg)
1.23
2.6
3
A
N.A
1.23