4.6.2.- Remote control connection (saving order).
• Never mind the structure, version and power of the equipment, there are three groups of two terminals for connecting, the
remote control or the saving order, and they are labelled in the equipment as «Remote Control».
• To order the flow dimming: Connect to the remote control terminals one of the normally open contacts of an astronomical clock
or timer. The saving level will start and remains meanwhile this contact is closed. To be installed by the client. DO NOT apply
voltage to these terminals, because they are free potential contacts.

CONNECTION DIAGRAM

ILUEST
IP/OP
IP/OP
R
N U
S
R-S-T-N
U-V-W-N
INPUT
OUTPUT
Fig. 12 Three phase ILUEST connection with BM478*
4.6.3.- Output connection.
• Connect the cables coming from the distribution lines to the output terminals (2
neutral stated in the labelling of the equipment and in the figures 12 and 13 of this manual.
• Either the light installatio existed before installing the ILUEST, or it were new, the load must be distributed correctly in order
to balance it among the phases.
IP/OP
N V
T
N W
R-S-T
REMOTE
CONTROL
CONNECTION DIAGRAM
R-N
U-N
INPUT
OUTPUT
Fig. 13 Single phase ILUEST connection with BM478*
), by respecting the phase rotation and
*
- 21 -
ILUEST
IP/OP
R
N U
REMOTE
CONTROL