Installation

Prepare location
It is recommended that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
1
Disconnect power.
2
Determine which venting method to use: roof, wall, or
nonvented.
3
Select a flat surface for assembling the range hood.
Place covering over that surface.
I WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING.
4
Using 2 or more people, lift range hood onto covered
surface.
Mounting the duct cover bracket
1
Determine and mark the centerline on the wall where the
canopy hood will be installed. Disconnect power.
2
Select a mounting height between a minimum of 24"
(61 cm) for an electric cooking surface, a minimum of
30" (76.2 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood.
Mark a reference line on the wall.
3
Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with
the centerline marked on the wall.
A.
Centerline
B.
Fastener locations
C.
Mounting height reference (hood bottom line)
4
Mark centers of the fastener locations through the
template to the wall.
IMPORTANT: All screws must be installed into wood.
If there is no wood to screw into, additional wall framing
supports may be required.
5
Remove the template.
6
Drill
" (4.8 mm) pilot holes at all locations where screws
3
1 6
are being installed into wood.
7
Install the 2 - 5 x 45 mm mounting screws. Leave a
(6.4 mm) gap between the wall and the back of the screw
head to slide range hood into place.
"
1
4
(6.4 mm)
8
A
C
B
"
1
4
Vent cover bracket installation
1
Attach vent cover bracket to wall flush to the ceiling using
2 - 5 x 45 mm screws.
A.
B.
C.
Install framing for hood support
If drywall is present, mark the screw hole locations.
Cut away enough drywall to expose 2 vertical studs at the
holes location indicated by the template.
Install two horizontal supports at least 4 x 2" between two
wall studs at the bottom and upper mounting holes
installation location.
The horizontal support must be flush with the room side
of the studs.
Use cleats behind both sides of the support to secure to
wall studs.
Reinstalll drywall and refinish
IMPORTANT- Framing must be capable of supporting 100 lbs.
8½" min. opening for ductwork
Centerline of
installation
space
Complete preparation
1
Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See "Venting Requirements" section.
2
Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3
Run the home power supply cable according to the
National Electrical Code or CSA Standards and local codes
and ordinances. There must be enough ½" conduit and
wires from the fused disconnect (or circuit breaker) box to
make the connection in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4
Use caulk to seal all openings.