Tt60 Serie Has Been Tested And Approved By The Following Standards; Technical Specifications; Safety Distance And Placement Of The Stove; Safety Distance To Inflammable - TermaTech TT60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 74
10.0 Approved by:
TEKNOLOGICAL INSTITUT, Energy and climate
Renewable Energy and Transport
Kongsvang Allé 29
8000 Aarhus C
www.teknologisk.dk
10.1 TT60 Series has been tested and approved by the following standards:
CE - EN13240 (EU)
DIN+ (Germany)
15A (Austria)
NS3058, 3059 (Norway)
AEA (UK)

11.0 Technical specifications:

Type
Nominal output
Height:
Width:
Depth:
Weight approx.:
Smoke nozzle diameter:
Average values for testing TT60:
Exhaust gas temperature 226 °C
Exhaust gas mass flow 5,3 g/s
Efficiency 83%
Flue draught 12 Pa

12.0 Safety distance and placement of the stove

12.1. Safety distance to inflammable

Distance to inflammable wall behind stove:
Distance to inflammable side wall:
TT60
Distance by corner placement of 45°:
TT60S
Photo 1
350
350
580
605
TT60
6kW
974mm
460mm
370mm
143kg
150mm
TT60S
TT60W
6kW
6kW
999mm
666mm
510mm
460mm
372mm
370mm
178kg
116k
75mm
Photo 1: