10.0 Approved by:
TEKNOLOGICAL INSTITUT, Energy and climate
Renewable Energy and Transport
Kongsvang Allé 29
8000 Aarhus C
www.teknologisk.dk
10.1 TT60 Series has been tested and approved by the following standards:
CE - EN13240 (EU)
DIN+ (Germany)
15A (Austria)
NS3058, 3059 (Norway)
AEA (UK)
11.0 Technical specifications:
Type
Nominal output
Height:
Width:
Depth:
Weight approx.:
Smoke nozzle diameter:
Average values for testing TT60:
Exhaust gas temperature 226 °C
Exhaust gas mass flow 5,3 g/s
Efficiency 83%
Flue draught 12 Pa
12.0 Safety distance and placement of the stove
12.1. Safety distance to inflammable
Distance to inflammable wall behind stove:
Distance to inflammable side wall:
TT60
Distance by corner placement of 45°:
TT60S
Photo 1
350
350
580
605
TT60
6kW
974mm
460mm
370mm
143kg
150mm
TT60S
TT60W
6kW
6kW
999mm
666mm
510mm
460mm
372mm
370mm
178kg
116k
75mm
Photo 1:
350mm
Photo 1:
50mm
Photo 2:
Photo 2
TT60
TT60S
50
50
347
363
TT60
TT60S
350
350
5
6
39