S+S Regeltechnik HYGRASGARD RFTF Notice D'instruction page 15

Masquer les pouces Voir aussi pour HYGRASGARD RFTF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

G
®
HYGRASGARD
Display
alternative output variables
By default, the first lines indicate the following measurements
with the corresponding units cyclically and consecutively:
temperature in °C, relative humidity in % r.H.
Backlighting is provided for improved legibility. The Modbus
interface allows the display to be individually configured,
both in the 7 and 14 segment range and in the dot-matrix
range.
®
HYGRASGARD
RFTF - Modbus
Type ⁄ WG01
RFTF - Modbus
R F T F - M O D B U S
R F T F - M O D B U S L C D
HYGRASGARD
®
RFTF - Modbus
Type ⁄ WG01
RFTF - Modbus - xx
R F T F - M O D B U S P
R F T F - M O D B U S P L C D
R F T F - M O D B U S P 5L
R F T F - M O D B U S P 5L L C D
R F T F - M O D B U S P D5
R F T F - M O D B U S P D5 5L
R F T F - M O D B U S P T D5 5L
R F T F - M O D B U S P T
R F T F - M O D B U S P T L C D
R F T F - M O D B U S P T 5L
R F T F - M O D B U S P T 5L L C D
Equipment:
RFTF - Modbus
Room humidity and temperature sensor
Measuring Range ⁄ Readout
Humidity (switchable)
0...100 % r. H. (default)
0...80 g ⁄ kg
3
0...80 g ⁄ m
0...85 kJ ⁄ kg
–20...+80 °C
0...100 % r. H. (default)
0...80 g ⁄ kg
3
0...80 g ⁄ m
0...85 kJ ⁄ kg
–20...+80 °C
Roomoperating humidity and temperature sensor
Measuring Range ⁄ Readout
Humidity (switchable)
0...100 % r. H. (default)
0...80 g ⁄ kg
0...80 g ⁄ m
3
0...85 kJ ⁄ kg
–20...+80 °C
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
(5 x as above)
P = Potentiometer (setpoint setter)
T = Presence push-buttons
The Modbus interface can be used to program
an alternative output variable instead of the
standard display.
In this case, the first line indicates the value
and index while the second line indicates the
corresponding unit statically.
The index identifies the display type:
Temperature
0...+50 °C
(MR)
(A.H.)
(ENT.)
(DP)
0...+50 °C
(MR)
(A.H.)
(ENT.)
(DP)
Output
Temperature
0...+50 °C
Modbus
(MR)
(A.H.)
(ENT.)
(DP)
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
(1 x as above)
Modbus
D5 = Rotary switch, 5-step
5L = LED display, multi-colour (5x)
15
Index 1 = temperature in °C
Index 2 = setpoint potentiometer in %
Index 3 = dew point in °C
Index 4 = relative humidity in % r.H.
Index 5 = absolute humidity in g ⁄ m³
Index 6 = mixture ratio in g ⁄ kg
Index 7 = enthalpy in kJ ⁄ kg
Output
Item No.
Display
Modbus
1201-42B6-6000-000
Modbus
1201-42B6-7000-000
Item No.
Display
1201-42B6-6001-005
1201-42B6-7001-005
1201-42B6-6119-005
1201-42B6-7119-005
1201-42B6-6012-841
1201-42B6-6120-841
1201-42B6-6121-841
1201-42B6-6047-005
1201-42B6-7047-005
1201-42B6-6051-005
1201-42B6-7051-005
Rev. 2019 - V23
RFTF - Modbus
Display

Publicité

Chapitres

Table des Matières
loading

Table des Matières