8 Maintenance Instructions
(cont.)
Pylon Sleeve
1
2
Remove the
Slide the pylon sleeve
rotation stop
and gaiter from the
screw.
spring housing.
Slot
Clean and relubricate bearing surface.
Use Sapphire Endure (928015) or equivalent PTFE loaded grease.
Re-assembly:
Ensure the rotation stop screw aligns with the slot in the pylon apply
Loctite 243 and tighten.
Replacement Gaiter available Part No. 534003