INSTALLATION, RELOCATION AND INSPECTION

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with
oily smoke.
• Where there is high-frequency or wireless equipment.
WARNING:
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be
generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
WARNING :
• The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc.
• Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

SPECIFICATIONS

Set name
MSZ-A09YV(H)
Model
Indoor
MSZ-A09YV
Outdoor
MUZ-A09YV(H)
Function
Cooling
Power supply
Capacity
kW
2.5
Input
kW
0.67
Indoor
kg
Weight
Outdoor
kg
Refrigerant filling
kg
capacity (R410A)
Indoor
IP code
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Indoor
dB(A)
37/29/21
Noise level
(High/Med./Low)
Outdoor
dB(A)
The installation location of the outdoor unit should be
at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak, pro-
Inverter-type
vide greater space between the outdoor unit and the
antenna of the affected device if operation of the air
fluorescent lamp
To prevent the effects
conditioner interferes with radio or TV reception.
of a fluorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent the
picture
distortion or
100 mm or
the noise.
more
1 m
or more
TV
1 m
or more
Cordless
phone or
Portable
Radio
3 m
phone
or more
NOTE:
MSZ-A12YV(H)
1. Rating condition
MSZ-A12YV
MUZ-A12YV(H)
Cooling —
Heating
Cooling
Heating
~ /N, 230V, 50Hz
Heating —
3.2
3.5
4.0
0.84
1.09
1.08
9
10
2. Guaranteed operating range
33
34
0.80
0.90
IP 20
IP 24
Cooling
1.64
4.15
38/30/21
39/31/22
38/30/22
Heating
46
47
48
CAUTION:
• Earth the unit.
Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.
wall, etc.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places,
etc.).
Well-
If the earth leakage breaker is not installed, it may cause an electric shock.
ventilated
dry place
Inspection and maintenance
200 mm or
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
more
• Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
dust, etc.
• It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.
Operating sound considerations
• Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.
• If an abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and work
are required.
WARNING:
Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
Outdoor
Indoor
MUZ-A09/A12YV MUZ-A09/A12YVH
32°C DB
46°C DB
46°C DB
Upper limit
23°C WB
21°C DB
-10°C DB
-10°C DB
Lower limit
15°C WB
27°C DB
24°C DB
24°C DB
Upper limit
18°C WB
18°C WB
20°C DB
-10°C DB
-15°C DB
Lower limit
-11°C WB
-16°C WB
If you have any questions, consult your dealer.