Installation Instructions - Novy 1768-2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

The installation comes under the exclusive responsibility of specialists.
The installer is held to respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
• The cut out sizes are:
Type
Cut size
Width
1768-2
850
• Ensure that there is a distance of 50 mm between the hob and the wall or sides.
• The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than
the hob.
• The piece of furniture or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 100 °C.
• The mural rods of edge must be heat-resisting.
• Not to install the hob to the top of a not ventilated oven or a dishwasher.
• To guarantee under the bottom of the hob casing a space of 20 mm to ensure a good air
circulation of the electronic device.
• If a drawer is placed under the work, avoid to put into this drawer flammable objects
(for example: sprays) or not heat-resistant objects.
• Materials which are often used to make worktops expand on contact with water. To protect
the cut out edge, apply a coat of varnish or special
sealant. Particular care must be given to applying
the adhesive joint supplied with the hob to prevent
any leakage into the supporting furniture. This
gasket guaranties a correct seal when used in
conjunction with smooth work top surfaces.
• The safety gap between the hob and the cooker
hood placed above must respect the indications of
the hood manufacturer. In case of absence of
instructions respect a distance minimum of 760 mm.
• Provide a ventilation opening from 4 mm just under
the worktop over a width of min. 600 mm for
sufficient cooling of the hob.
• The connection cord should be subjected, after
building, with no mechanical constraint, such for
example of the fact of the drawer.
Cut size of flush mouting
Depth
Width
Depth
490
904
524
Stick the gasket (2) two
millimeters from the external
edge of the glass, after removing
the protection sheet (3).
Glass size
Radius
Width
7
900
74
Depth
Thickness
520
4

Publicité

Table des Matières
loading

Table des Matières