My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same House
Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or
Marmitek Security Console installed in your house. These components will translate the radio
signals to the Marmitek X-10 signal on the power line. Only one Transceiver should be
installed for all remotes and sensors set to the same House Code.
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of your
remotes is not sufficient. The TM13 is using so called collision detection to prevent signals to
be disturbed when more than one TM13 is transmitting. TM13's will wait for a quite power
line before transmitting their data. To prevent your Marmitek X-10 System to become slow or
to prevent dimming from becoming less smooth, make sure that the TM13 units are placed as
far away from each other as possible.
User manual LM12 Lamp Module
1. Set the House Code and Unit Code dial on the front of the Module to the desired codes.
2. Plug the lamp into the Module.
3. Plug the Module into a wall outlet.
You are now able to control your Module with any Marmitek X-10 Controller. It is also possible
to control the Module locally. Just switch the regular switch off and on shortly and the lamp will
come on (auto sense function).
Technical data
Supply voltage:
Supply current :
Making capacity:
Dimmer Speed:
Signal sensitivity:
Input impedance:
X-10 transmission:
X-10 key codes to respond to:
When using 3-phase installation:
Fuse:
Ambient temperature:
Dimensions:
Environmental Information for Customers in the European Union
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its
packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product
should be disposed of separately from regular household waste streams. It is your responsibility to dispose
of this and other electric and electronic equipment via designated collection facilities appointed by the gov-
ernment or local authorities. Correct disposal and recycling will help prevent potential negative conse-
quences to the environment and human health. For more detailed information about the disposal of your old equip-
ment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
4
230V ±10% 50 Hz
< 20 mA capacitive
40W to 300W (normal light bulbs only)
4.4s from 100% to 0% ±0.2s
15 mVpp min 50 mVpp max at 120 kHz
> 55 Ohm (L - N) at 120 kHz
1 puls burst on 0, 60 and 120 degrees.
All units Off, All Lights On, On, Off, Dim, Bright.
FD10 (three times) or CAT3000 needed
F 3A 250V 5 x 20 mm
-10° C to + 50° C (operation) - 20° C to + 70° C (storage)
52x122x33mm (without plug)
© MARMITEK