Josef Kihlberg JK20V779L
KUDA PACKAGING
7
Before all maintenance tasks on the
stapler always first disconnect it from
the air supply.
7.1 CLEANING THE STAPLER
This stapler does not require special servicing. It only
needs regular cleaning with a non-aggressive (non-
corrosive) cleaner agent. Do not remove any parts for
cleaning purposes!
Check the proper functioning of all safety
devices daily. Make especially sure that:
–
the trigger works smoothly, the door stays in place
and the magazine lid does not open itself.
–
all screws and nuts are securely tightened.
–
the stapler is regularly lubricated (refer to chapter
5.2).
7.2 REMOVING JAMMED STAPLES
To remove a staple which has become jammed:
– Pry the door open with a screw driver (Fig. 5/1) .
There are three notches in the door to simplify the
disassembling.
– Remove the door.
– Check the canal for defective staples.
– Insert the door into the rear nozzle plate and push
until it clicks shut.
The three notches at the door must be
assembled to the front.
SERVIS A NAHRADNÍ DÍLY
8
www.kuda-packaging.com
PREVENTIVE AND CORRECTIVE MAINTENANCE
+420 607 237 237
info@kuda-packaging.com
1
Fig. 5
servis@josef-kihlberg.eu
04.14