ICE MAKER INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION DE
ICE MAKER SAFETY................................................................................... 1
INSTALLATION INSTRUCTIONS ............................................................... 2
Unpack the Ice Maker............................................................................... 2
Location Requirements............................................................................. 2
Electrical Requirements ............................................................................ 3
Water Supply Requirements..................................................................... 3
Vacation or Extended Time Without Use ................................................. 3
Connect Water Supply.............................................................................. 3
Drain Pump Installation............................................................................. 4
Drain Connection ...................................................................................... 7
Door Reversal-Side Swing Only............................................................. 8
Leveling ................................................................................................... 10
Cleaning .................................................................................................. 10
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING
: To reduce the risk of fire, electric shock, or injury when using your ice maker, follow these basic
precautions :
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
W10541636C
MACHINE À GLAÇONS
Table of Contents/Table des matières

ICE MAKER SAFETY

Your safety and the safety of others are very important.
DANGER
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
SÉCURITÉ DE LA MACHINE À GLAÇONS ............................................. 12
INSTRUCTIONS D'INSTALLATION ......................................................... 13
Déballage de la machine à glaçons ....................................................... 13
Exigences d'emplacement ..................................................................... 13
Spécifications électriques....................................................................... 13
Spécifications de l'alimentation en eau.................................................. 14
Vacances ou longue période d'inutilisation ........................................... 14
Raccordement à la canalisation d'eau................................................... 14
Installation de la pompe de vidange ...................................................... 15
Raccordement au conduit vidange ........................................................ 18
Porte à ouverture latérale uniquement................................................... 19
Nivellement ............................................................................................. 21
Nettoyage ............................................................................................... 22
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
Disconnect power before manually cleaning the inside components.
Disconnect power before servicing.
Replace all parts and panels before operating.
Use two or more people to move and install ice maker.

Publicité

Table des Matières
loading

Sommaire des Matières pour KitchenAid W10541636C

  • Page 1: Table Des Matières

    Do not remove ground prong. Disconnect power before servicing. Do not use an adapter. Replace all parts and panels before operating. Do not use an extension cord. Use two or more people to move and install ice maker. SAVE THESE INSTRUCTIONS W10541636C...
  • Page 2: Installation Instructions

    State of California Proposition 65 Warnings: WARNING: This product contains one or more chemicals known to the State of California to cause cancer. WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.
  • Page 3: Electrical Requirements

    If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis Electrical Requirements system needs to be a minimum of 40 to 60 psi (276 to 414 kPa). NOTE: The reverse osmosis system must provide 1 gal. (3.8 L) of WARNING water per hour to the ice maker for proper ice maker operation.
  • Page 4: Drain Pump Installation

    NOTE: To allow sufficient water flow to the ice maker a 6. Remove and discard the short, black plastic tube from the end minimum ¹⁄₂" diameter home supply line is recommended. of the water line inlet. 7. Thread the nut onto the end of the tubing. Tighten the nut by hand.
  • Page 5 If Ice Maker Is Currently Installed Drain Pump Installation NOTE: If ice maker is not installed, please proceed to “Drain NOTE: Do not kink, smash or damage tubes or wires during Pump Installation” section. installation. 1. Push the selector switch to the Off position. 1.
  • Page 6 Parts Locations Drain Pump Installed A. Drain pump installed 8. Align the 2 screw holes at the rear of the pump. Use two #8-32 x ³⁄₈" screws, supplied. See “Parts Locations” illustration. 9. Connect drain tube to ice maker bin outlet (⁵⁄₈" I.D.), using ⁷⁄₈" A.
  • Page 7: Drain Connection

    15. Attach ¹⁄₂" I.D. x 10 ft (3 m) drain tube to pump discharge tube. IMPORTANT: A drain pump is necessary when a floor drain is not See “Parts Locations” illustration. available. A Drain Pump kit, Part Number 1901A, is available for purchase.
  • Page 8: Door Reversal-Side Swing Only

    Connecting the Drain Remove Stainless Steel Door Wrap Panel (on some models) After ensuring that the drain system is adequate, follow these steps to properly place the ice maker: WARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong.
  • Page 9 6. Remove the screw and door stop at corner D. Remove the Top Hinge screw and end cap at corner B. Place the door stop at corner B, and tighten screw. Place the end cap at corner D, and tighten screw. A.
  • Page 10: Leveling

    3. Install the white decorative screws on the opposite side of the 5. Push up on the top rear of the ice maker and locate the door. leveling legs that are on the bottom rear of the ice maker. 6. Follow the instructions in Step 4 to change the height of the legs.
  • Page 11 7. Remove the right-hand and left-hand screws. Lift the cutter On Some Models grid up and out. After removing the ice scoop, remove the holder by NOTE: Make sure the plastic spacer from the right-hand side removing the 2 screws. of the cutter grid bracket stays with the cutter grid.
  • Page 12: Sécurité De La Machine À Glaçons

    SÉCURITÉ DE LA MACHINE À GLAÇONS Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 13: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION Vérifier que la canalisation d’alimentation en eau n’est pas endommagée, déformée ou coincée entre la machine à Déballage de la machine à glaçons glaçons et la caisse de l’appareil. Vérifier que la canalisation d’évacuation (sur certains AVERTISSEMENT modèles) n’est pas endommagée, déformée ou coincée entre la machine à...
  • Page 14: Spécifications De L'alimentation En Eau

    Il faut un circuit d’alimentation électrique CA seulement de 115 volts, 60 Hz, de 15 ou 20 ampères, mis à la terre Vacances ou longue période conformément aux instructions du Code national de l’électricité et d’inutilisation des codes et règlements locaux. Il est recommandé...
  • Page 15: Installation De La Pompe De Vidange

    Installer le manchon et l’écrou à compression sur le tuyau REMARQUE : Pour éviter les vibrations, veiller à ce que le en cuivre (voir l’illustration). Insérer l’extrémité du tuyau de tuyau en cuivre ne soit pas en contact avec les parois latérales sortie aussi profondément que possible dans l’extrémité...
  • Page 16 Canalisation d’alimentation en eau Si la machine à glaçons est installée REMARQUE : Si la machine à glaçons n’est pas installée, passer à la section “Installation de la pompe de vidange”. 1. Appuyer sur le commutateur de sélection pour le mettre en position d’arrêt.
  • Page 17 Tube de vidange Encoche de patte de montage de la pompe de vidange ⁷⁄₈ ⁷⁄₈ A. Bride de tuyau réglable de " C. Bride de tuyau réglable de " B. Tube de vidange (entre le bac à D. Entrée du réservoir de la A.
  • Page 18: Raccordement Au Conduit Vidange

    Tube de ventilation Raccordement au conduit vidange REMARQUE : Ne pas coincer, déformer ou endommager le tube d’aération. Vérifier qu’il n’est pas endommagé, déformé ou coincé entre le placard et la machine à glaçons. Vidange par gravité Raccorder le tuyau de vidange de la machine à glaçons à votre drain de vidange conformément aux codes et règlements locaux et provinciaux.
  • Page 19: Inversion Du Sens D'installation De La Porte -Porte À Ouverture Latérale Uniquement

    3. Vérifier à nouveau la machine à glaçons pour s’assurer qu’elle Système avec pompe de vidange (sur certains modèles) est bien d’aplomb. Voir la section “Nivellement”. 4. Si le code sanitaire local l’exige, sceller la caisse sur le IMPORTANT : plancher à...
  • Page 20 Inversion du sens de montage de la butée de porte et Inversion du sens de montage des charnières des protections d’angle 1. Dévisser et ôter la charnière supérieure. Réinstaller les vis dans les trous vides de la charnière. AVERTISSEMENT 2. Ôter les vis du côté opposé inférieur de la caisse de la machine à...
  • Page 21: Nivellement

    Charnière inférieure 3. Installer les vis blanches décoratives sur le côté opposé de la porte. AVERTISSEMENT Risque de choc électrique Brancher sur une prise à 3 alvéoles reliée à la terre. Ne pas enlever la broche de liaison à la terre. Ne pas utiliser un adaptateur.
  • Page 22: Nettoyage

    4. Au moyen d’une clé à molette, modifier la hauteur des pieds 5. Débrancher le faisceau de câblage du côté gauche de la grille comme suit : de coupe. Tourner le pied de nivellement vers la droite pour abaisser ce côté de la machine à glaçons. Tourner le pied de nivellement vers la gauche pour soulever ce côté...
  • Page 23 9. Déconnecter le support de pompe du réservoir et débrancher 11. Laver les composants intérieurs (la grille de coupe, l’extérieur la pompe de vidange du bac à eau. des tuyaux et le bac à eau), le bac d’entreposage des glaçons, le joint étanche de la porte et la pelle à...
  • Page 24 9/14 ©2014 Whirlpool. All rights reserved. Printed in U.S.A. W10541636C Tous droits réservés. Imprimé aux É.-U.