• Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided it shall be made
underneath the power line and as nearly as possible at right angles to it.
• If connec ng leads and electric animal fence wires are installed near an overhead power line, the clearances shall not be less
than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Less than or equal to 1 000
Greater than 1 000 and less than or equal to 33 000
Greater than 33 000
• If connec ng leads and electric animal fence wires are installed near an overhead power line, their height above the ground
shall not exceed 3 m.
This height applies either side of the orthogonal projec on of the outermost conductors of the power line on the ground
surface, for a distance of:-
-
2 m for power lines opera ng at a nominal voltage not exceeding 1 000 V;
-
15 m for power lines opera ng at a nominal voltage exceeding 1 000 V.
• Electric animal fences intended for deterring birds, household pet containment or training animals such as cows need only be
supplied from low output energizers to obtain sa sfactory and safe performance.
• In electric animal fences intended for deterring birds from roos ng on buildings, no electric fence wire shall be connected to
an earth stake. A warning sign shall be fi ed to every point where persons may gain ready access to the conductors.
• Where an electric animal fence crosses a public pathway, a non-electrifi ed gate shall be incorporated in the electric animal
fence at that point or a crossing by means of s les shall be provided. At any such crossing, the adjacent electrifi ed wires shall
carry warning signs.
• Any part of an electric animal fence that is installed along a public road or pathway shall be iden fi ed by electric fence warning
signs (G6020) at regular intervals that are securely fastened to the fence posts or fi rmly clamped to the fence wires.
• The size of the warning sign shall be at least 100mm x 200mm.
• The background colour of both sides of the warning sign shall be yellow. The
inscrip on on the sign shall be black and shall be either:
-
the substance of "CAUTION: Electric Fence" or,
-
the symbol shown:
• The inscrip on shall be indelible, inscribed on both sides of the warning sign and have a height
of at least 25mm.
• Ensure that all mains operated, ancillary equipment connected to the electric animal fence circuit
provides a degree of isola on between the fence circuit and the supply mains equivalent to that provided by the energizer.
• Protec on from the weather shall be provided for the ancillary equipment unless this equipment is cer fi ed by the
manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protec on IPX4.
This energizer complies with interna onal safety regula ons and is manufactured to interna onal standards. Gallagher
reserves the right to make changes without no ce to any product specifi ca on to improve reliability, func on or design. E & OE.
The author thanks the Interna onal Electrotechnical Commission (IEC) for permission to reproduce Informa on from its Interna onal
Publica on 60335-2-76 ed.2.2 (2013). Annex BB.1. All such extracts are copyright of IEC, Geneva, Switzerland. All rights reserved.
Further informa on on the IEC is available from www.iec.ch. IEC has no responsibility for the placement and context in which the
extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.
Save these instruc ons.
6
Power line Voltage V
Clearance m
3
4
8