Bosch GAL 1215 CV Professional Notice Originale page 7

Masquer les pouces Voir aussi pour GAL 1215 CV Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
OBJ_BUCH-2865-001.book Page 7 Tuesday, June 28, 2016 11:59 AM
 Do not cover the ventilation slots of the battery charg-
er. Otherwise, the battery charger can overheat and no
longer operate properly.
Products sold in GB only: Your product is fitted with a
BS 1363/A approved electric plug with internal fuse (ASTA
approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be
cut off and an appropriate plug fitted in its place by an author-
ised customer service agent. The replacement plug should
have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains sock-
et elsewhere.
Product Features
The numbering of the product features refers to the illustra-
tion of the battery charger on the graphics page.
1 Battery pack*
2 Green battery charge indicator
3 Charging compartment
*Accessories shown or described are not part of the standard de-
livery scope of the product. A complete overview of accessories
can be found in our accessories program.
Technical Data
Battery Charger
Article number
Battery charging voltage
(automatic voltage detection)
Charging current
Allowable charging temperature
range
Charging time for battery
capacity, approx.
– 1.3–1.5 Ah
– 2.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01:2014
Protection class
Operation
Starting Operation
 Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is plugged into the socket outlet and the
battery 1 is inserted into the charging compartment 3.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
Bosch Power Tools
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Note: The charging procedure is only possible when the bat-
tery temperature is within the allowable charging tempera-
ture range, see "Technical Data" section.
Meaning of the Indication Elements
Flashing Battery Charge Indicator 2
Continuous Lighting of the Battery Charge Indicator 2
in the allowable charging temperature range, and cannot be
charged for this reason. The battery is charged as soon as the
allowable charging temperature range is reached.
When the battery is not inserted, continuous lighting of the
battery charge indicator 2 indicates that the mains plug is in-
serted in the socket and that the battery charger is ready for
GAL 1215 CV
operation.
2 607 226 1..
Troubleshooting – Causes and Corrective Meas-
V
3.6 – 12
ures
mA
1500
Cause
Continuous lighting of the battery charge indicator 2
°C
0 – 45
No charging procedure possible
Battery not (properly)
(80%)
100%
inserted
min
(50)
65
Battery contacts
min
(65)
80
contaminated
1 – 3
kg
0.36
Battery pack defective
/ II
Battery charge indicator 2 does not light up
Mains plug of battery charger
not plugged in (properly)
Socket outlet, mains cable or
battery charger defective
Working Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaningful
and does not indicate a technical defect of the battery charg-
er.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.
English | 7
The charging procedure is signalled by a
flashing battery charge indicator 2.
Continuous lighting of the battery
charge indicator 2 indicates that the
battery is fully charged or that the
temperature of the battery is not with-
Corrective Measure
Properly insert battery into
battery charger
Clean the battery contacts
(e.g. by inserting and remov-
ing the battery several times)
or replace the battery
Replace the battery
Insert mains plug (fully) into
the socket outlet
Check the mains voltage;
have the battery charger
checked by an authorised
after-sales service agent for
Bosch power tools
1 609 92A 2MH | (28.6.16)

Publicité

Table des Matières
loading

Table des Matières