KitchenAid 720-0954R Instructions D'installation Et Guide D'utilisation Et D'entretien page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.
Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4.
Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
A
B
A. Locking screw
B. Bottom collar
C. Mounting hole
5.
Slide the drawer with the 20lb LP gas fuel tank back into
the cabinet. Turn the tank tray locking bracket clockwise
90º to tighten.
A
A. Tank tray locking bracket
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected grill location in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition,
and local codes. For conversion to Natural gas, the Natural Gas
Conversion Kit supplied with the grill (on some models) or the
Natural Gas Conversion Kit Part Number 710-0003 must be
used. See "Assistance" section for information on ordering.
C
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
Follow instructions for converting to Natural gas in the "Gas
Conversions" section of this manual or the instructions supplied
with Natural Gas Conversion Kit Part Number 710-0003.
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the grill
and should be in a location that allows ease of opening and
closing. Do not block access to the shutoff valve. The valve is
for turning on or shutting off gas to the grill.
39
A. Gas supply line
B. Shutoff valve "open" position
C. To grill

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

720-0954r lp730-0954r730-0954r ng

Table des Matières