Varnished Products (If Present); Enamelled Products (If Present); Chromium-Components (If Present); Maintenance Of The Smoke Exhaust - LA NORDICA FORTUNA Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

vARNIsHED PRODUCTs (IF PREsENT)

After some years of product use a change in the varnished details colour is totally normal. This is due to the considerable temperature range
the product is subject to whenever in use and to the varnish ageing of time passing by.
ATTENTION: before any possible application of the new varnish, do clean and remove all the traces from the surface which has to
be varnished.

ENAMELLED PRODUCTs (IF PREsENT)

For the cleaning of enamelled surfaces use soap water or not aggressive and not chemically abrasive detergents.
After the cleaning do NOT let soapy water or any cleanser dry but remove them immediately.
DO NOT use sandpaper or steel wool.

CHROMIUM-COMPONENTs (IF PREsENT)

If the components become bluish due to overheating, this can be solved with a suitable product for cleaning. DO NOT use abrasives or
solvents.

MAINTENANCE OF THE sMOkE EXHAUsT

By using the device continuously, the lubricant of the guides tends to run out progressively in time making their sliding more difficult and
noisy. For this reason, together with each device a high temperature grease is supplied in order to make the lubrication of the guides possible
for the user, in case it becomes necessary (excessive noise or reduction of smoothness).
Lift the smoke exhaust (pos.
With the supplied grease, lubricate the wheels pivots and the smoke exhaust on the contact part with the wheels;
Lean the smoke exhaust on the wheels, then insert the smoke pipe;
CAUTION: use exclusively the grease supplied by La NORDICA.

CALCULATION OF THE THERMAL POWER

There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the calorific value necessary for a properly insulated room is 30 kcal/h per m
external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 35 W/m
Let's suppose one wishes to heat a room of 150 m
W/m
= 5250 W or 5,25 kW. As main heating, a 8 kW device is therefore sufficient.
3
Fuel
Dry wood (15% humidity)
Wet wood (50% humidity)
Wood briquettes
Brown coal briquettes
Normal anthracite
Coke
Natural gas
Naphtha
Electricity
32
Picture 10
Pos.A);
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
Approximate combustion value
Unit
kcal/h
kg
kg
kg
kg
kg
kg
m
3
L
kW/h
.
3
kW
3600
4.2
1850
2.2
4000
5.0
4800
5.6
7700
8.9
6780
7.9
7800
9.1
8500
9.9
860
1.0
ENgLIsH
Required quantity in relation to
1 kg of dry wood
1,00
1,95
0,84
0,75
0,47
0,53
0,46
0,42
4,19
(for an
3
x 35
3