TECHNICAL DATA

Definition in according to:
Constructive system
Nominal thermal power in kW
Efficiency in %
smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Depression by rating calorific value in Pa - wood
Hourly consumption in kg / h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s - wood
Exhaust gas temperature in °C - wood
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
fire prevention safety distances
m
riscaldabili (30 kcal/h x m
3
(#) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
of the stoves is:favourable type of building (30 kcal/h x m
of building (50 kcal/h x m
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
The declared technical data have been achieved by burning beech wood class "A1" according to the requirement UNI EN ISO 17225-5 and wood
moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and some specific adjustments
on the appliance could be needed.

TECHNICAL DEsCRIPTION

The chimney stoves of LaNORDICA s.p.A. are suitable to heat living spaces for some periods. As fuel, wood logs are used. The appliance
works as an intermittent operating appliance.
The stove is made of sheets in galvanized steel and of enamelled cast iron. The hearth is internally sheathed refractory (NORDIKER) and inside
it there is a turning and extractable grate.
The hearth is equipped with a large feeding door.
ACCEssORIEs
The heating of the environment is made by convection: (70%): the air passage through the double mantel of the stove releases heat into the
environment.
The stove is NOT endowed with adjustable air entrances.
The adjustment of the registers necessary to reach the rated calorific yield is the following one:
20
)
(#)
3
).
3
POKER
GLOVE
sERIEs
sERIEs
Hourly consumption in kg/h
1,8
); less favourable type of building (40 kcal/h x m
3
PRIMARY air
sECONDARY air
PRE-ADJUSTED
PRE-ADJUSTED
ENgLIsH
MIgNON
EN 13240
2
4
53,5
100
4 - 200x200 Ø200
12 ( 1,2 mm H
O)
2
1,8
0,42
13,26
297
190 x 165
240 x 405 x 235
/
Movable - flat
817
378
417
56
Chapter FIRE sAFETY
115
); unfavourable type
3
TERTIARY AIR
PRE-ADJUSTED