NVM175 Handbook
0 for no standby and no remote on/off (enable).
= Blank for Open Frame or "-" followed by U for U chassis, C for U chassis with cover, K for custom
g
chassis with cover and IEC inlet
= Blank for standard upright output connector or "-" followed by
h
R for the right angle output connector.
S for the screw terminal output.
= Blank for standard leakage or "-" followed by
i
L for low leakage.
Zx for custom leakage which is less than standard leakage and x is a number between 1 and 9 for
different custom leakage current options.
jkl
= Blank for standard output setting or '-' followed by three numbers from 0 to 9 which denotes various
output voltages and currents within the specified range of channel 1 output for a particular unit.
m
= Blank for dual fuse input or -FL for single fuse input in the Live line
Input Parameters
Parameter
Nominal input voltage
Input voltage range
Input frequency range
Maximum input current
All ratings apply for ambient temperatures up to 50°C. From 50 to 70°C the total output power and current
ratings are both derated at 2.5% per deg C.
Output Parameters
There are three NVM175 standard models with various options, and non-standard models with output
parameters shown in the tables below.
Output channel
designation
Channel 1
Standby output
Variations and limitations of use:
1. NVM175 PSUs can output 180W from channel 1 plus 10.4W maximum from the standby output.
2. Component temperatures must be monitored in the end use application as described in the "Cooling For
Unit" section.
3. All ratings apply for ambient temperatures up to 50°C. From 50 to 70°C the total output power and current
ratings are both derated at 2.5% per deg C.
4. NVM1D product has 18 way connector. Maximum storage is 65°C.
Non-Standard Models:
Non- Standard model: X50015# (# can be any letter), (modified NVM1-1T000-S1-K-S-L)
Output Channel
designation
CH1
Standby
Additional Variations and limitations of use for Non-Standard model X50001#
1. Ratings apply for ambient temperatures up to 60°C. From 60 to 65°C the total output power and current
ratings are both derated at 2.5% per deg C.
2. Component temperatures must be monitored in the end use application as described in the "Cooling For
Unit" section.
60601-1
100 - 240 Vac
90 - 264Vac
45 - 63Hz
3A rms
Voltage
Vout (V)
nom.
T
12
F
15
G
24
S
12
S1
12
S2
12
S3
12
S4
12
S5
5
S6
5
Voltage
Vout
T
12
S1
12
Page 15 of 23
60950-1 & 62368-1
100 - 240 Vac
90 - 264Vac
45 - 440Hz
3A rms
Adjustment
Output
range (V)
current (A)
12 - 15.5
15
12 - 15.5
15
24 - 28.5
7.5
Fixed
0.2
Fixed
0.2
Fixed
0.2
Fixed
0.2
12 - 13
0.8
Fixed
0.5
Fixed
0.5
Adjustment
Output
Range (V)
Current (A)
12 - 15.5
11.67A
Fixed
0.2A
Maximum
power (W)
180
180
180
2.4
2.4
2.4
2.4
10.4
2.5
2.5
Maximum
Power (W)
140
2.4
17814 issue 17, September 2019