Installation of the electrics
The electrics may only be installed by a qualifi ed electrician in accordance with the VDE and EVU guidelines.
Information on assembly of the sauna furnace and the control device can be found in the enclosed assembly
instructions.
Assembly recommendations
Please pre-drill all screw connections in order
to avoid any damage to the wooden sections.
The following symbol in the instructions will
indicate when this is necessary:
To pr Door leaf
The adjustable eccentric, permits easy adjustment of the glass door leaf even at a later point in time.
The internal parts of the door fi ttings are removed, and the eccentric is rotated in the appropriate direction.
During installation of the door grips, ensure that the metal grip piece is on the outside of the door.
event the dropping of the glass door, tighten the allen screw of the braces fi rmly.
Cable routing in the front wall
Saunas with external stove controller (Classic OS / BioAktiv BIOS)
R1:
For the cable from
the stove controller module
to the sauna stove
R2:
For the cable from
the stove controller module
to the control unit
R3:+ R4
Reserve
Note:
With the exception of the door element,
a 2 cm deep groove must be located on the
upper edge of the elements.
The groove on the lower edge is only 8 mm deep.
VARIA
Assembly variants
We recommend 2 building variants each time which have proved themselves to be particularly practical.
Other possibilities for the arrangement of the wall elements are also feasible, for which the following
conditions are to be followed:
The sauna furnace and the control unit are usually mounted on the supply air element
The wall element with the outgoing air opening must be confi gured diagonally to the
supply air opening, in order to guarantee optimal air circulation in the sauna aisle.
The supply air element can be installed left or right of the door.
With the exception of the supply air element, the wall elements do not have
any specially determined interior or exterior side.
Before installation, the door element can be turned so that later the door can open to
the left or right.
The sauna can also be built in its mirror image.
Technische Änderungen vorbehalten!