Télécharger Imprimer la page

Absaar HF-1202 Instructions D'utilisation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
TROUBLESHOOTING
Problem
The LED indicator does not
illuminate when the charg-
ing cable is connected to the
battery.
The green LED light stays on
even when battery is not full.
The red LED light turns on.
SPECIFICATIONS
Specifications are subject to change without notice.
Rated voltage & power
Input current
Maximum output current
Constant current charging voltage
Floating charge voltage
Battery type
Ambient temperature
Weight
Correct disposal of this product - If the symbol of a crossed out trash can appears on a
product, it means that this product is subject to the European Directive 2002/96/EC. All old
electrical and electronic devices must be disposed of separately from household rubbish
at designated places. The proper disposal of old devices avoids damage to the environ-
ment and your personal health. You can obtain more information on the disposal of old
devices by contacting your municipal administration, the disposal office or the place where
you purchased the product.
Cause
Loose connection at the
connection terminals.
No AC power at outlet.
Overheating shutdown
The battery voltage is too
low.
The charger clamps are
not connected properly to
the battery terminals.
Reverse polarity
230 – 240V ~ 50 Hz, 110 W
0,5 A
2A
<14,4 V DC
13,5 ± 0,2 V DC
12 V lead-acid / VRLA maintenance free (Gel and AGM)
-30°C – 40°C
480 g
Solution
Check the connection.
Ensure power is present at outlet.
Clean dirty ventilation openings or remove
objects covering the unit. Place the unit in a
cooler location.
Check the battery voltage with a multimeter.
Recycle the battery if the battery voltage is
too low.
Check the connection and re-attach the
clamps to the terminals.
Check the polarity