Controller Specifications; Controller Outline - Varian Turbo-V 250 Mode D'emploi

Masquer les pouces Voir aussi pour Turbo-V 250:
Table des Matières

Publicité

CONTROLLER SPECIFICATIONS

Input:
Voltage
Frequency
Power
Output:
Voltage
Frequency
Power
Operating
temperature
Storage temperature
Fuse (mains)
Auxiliary connectors
100, 120, 220, 240
Vac ±10%, 1-phase
47 to 63 Hz
450 VA maximum
54 Vac nominal ±10%,
3-phase
933 Hz, ±2%
150 W maximum
0 °C to +40 °C
-20 °C to +70 °C
T3A (slow blow)
disregarding the mains
P17 INPUT/OUTPUT mains
and signals (pins)
J16 pump connector
(socket)
P3 hand held terminal
connector (pins)
Controller model outline
Radio interference
suppression
Safety standard
Weight

CONTROLLER OUTLINE

The outline dimensions for the Turbo-V 250 controller
model 969-9504 are shown in the following figure.
50
TECHNICAL INFORMATION
EN 55011 class A group 1
IEC1000-4-2,
1000-4-3, 1000-4-4
EN 61010-1
4 Kg (8.8 lbs)
87-900-856-01 (B)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

969-9504

Table des Matières