Interfaces
Valeur de vide des éjecteurs
Parameter
515 (0x0203)
Description
System vacuum for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read only
Value range
0 ... 999
Default value
-
Unit
mbar
EEPROM
no
Erreurs des éjecteurs
Parameter
130 (0x0082)
Description
Errors of ejector
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint8
Length
16 Byte
Access
read only
Value range
Bit 0 = Measurement range overrun
Bit 1 = Vacuum calibration failed
Default value
0
Unit
-
EEPROM
no
Erreurs de l'unité de commande
Parameter
130 (0x0082)
Description
Errors of Control Unit
Index
16
Datatyp
uint8
Length
1 Byte
Access
read only
Value range
Bit 0 = Internal error: data corruption
Bit 1 = Internal error: bus fault
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Secondary voltage too low
Bit 5 = Secondary voltage too high
Bit 6 = Supply pressure too low (<1,9bar) or too high (>6,3bar)
Bit 7 = Error in one or more ejectors
Default value
0
Unit
-
EEPROM
no
42 / 76
FR · 30.30.01.01598 · 02 · 01/19