Contents
- Burner description
RANGE NAME BY FUEL TYPE
MAX GAS Gas
MODEL SIZE (Gas: kW; Oil: kg/h)
MAX 40
40 kW
EMISSION COMBUSTION TYPE
LN
Low NOx Class 3 GAS EN676 (<80 mg/kWh)
-
Standard Class 2-GAS EN676 (<120 mg/kWh)
OPERATION TYPE
P
1 stage
HEAD TYPE
TC
Short head
TL
Long head
FUEL
Natural gas
LPG
LPG
ELECTRICAL SUPPLY TO THE SYSTEM
230-50-60 230 Volt, 50-60 Hz
CONTROL BOX
TW
Thermowatt
Scope of delivery
The burner is delivered in a modular system of
packagings i.e. separate set/box:
BBCH: Burner Body with Combustion Head
with flange.
- 1 bag including : - multilanguage technical manual.
- wieland plug.
- spanner.
- screws, nuts and washer.
GT: separate Gas Train
KIT & ACS are managed and delivered separately
A1
10
5
420010372804
MAX GAS 40 LN P TC - 230-50-60 TW
113
8
3
16
F6
M1
17
14
15
A1
E-BCU Gas control unit
F6
Air pressure switch
M1
Electric motor
T1
Ignition transformer
Y
Graduated rod for head adjustment
3
Air regulation in the burner head
5
Housing
8
Blast tube
10
Wieland socket
14
Burner hood
15
Burner flange
16
Reset key
17
Measuring point for gas pressure
103B Air regulation
113
Air intake
KIT & ACS delivered separately
Y
www.ecoflam-burners.com
EN
103B