The WESTFIRE WF UNIQ 17, 18 stoves are lined with heat deflection panels and baffles, these panels are designed to
ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles should
not be removed other than for cleaning the stove. Any defective panels should be replaced.
Connection to chimney
The WESTFIRE UNIQ 17, 18 stove is factory set up with a top flue outlet, this can altered to a rear connection by
unbolting top collar and rear cover plate and exchanging collar and plate. Care should be taken to ensure an airtight
fit when refitting collar and plate. A decorative cover plate is included with every stove to cover the hole in the
convection top plate.
This collar allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney.
Commissioning and handover
Ensure loose parts are fitted in accordance with the instructions for "Fitting the loose parts" given in the instruction
booklet. On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, a
small fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely into
the atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left with
the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on
the stove and notify them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use
a fireguard to BS 6539 in the presence of children, aged and/or infirm persons.
Operating your stove – WESTFIRE UNIQ 17, 18
The first lighting of your stove
The heat-resistant paint on your stove will cure and harden the first time you light your appliance. The curing process
produces a good deal of smoke and odour, it is therefore important that the first time you light your stove the room
should be well ventilated. During the process it is important to open and close the stove door periodically (every
30 mins) during the first couple of firings therefore preventing the door seal cord around the door from sticking and
coming away from the door. Once the heat-resistant paint has hardened the smell will disappear. This stove is NOT
designed to be used with the door open, the stove door must be kept closed except when lighting the stove, adding
firewood or removing ash in order to prevent flue gases from escaping.
Lighting your appliance
Quality Firelighters should be used when lighting the stove. (Never use mentholated spirit, petrol or other flammable
liquids). Lighting your stove firelighters will be more reliable and easier than using paper.