Sunrise spas ultimate collection OM-SRULTIMATE-19 Guide D'utilisation page 66

Table des Matières

Publicité

LED Light(s) Do Not Come On When Light Key is Pressed
Probable
Light fuse blown in spa pack
cause #1:
Action:
Locate and test/replace light fuse in spa pack Call dealer if problem persists.
Probable
In -line or on board fuse blown in LED controller
cause #2:
Action:
Locate and test/replace light fuse in LED control box.
No Air/Water Mixture Coming From a Jet
Probable
Air control is closed
cause #1:
Action:
Open air control
Probable
Water volume through jet is too low to draw air
cause #2:
Action:
Increase water volume by turning jet face
Probable
Adjustable jet internal is loose.
cause #3:
Action:
Tighten jet internal
Probable
Jet internal is broken or damaged
cause #4:
Action:
Replace jet internal with another one from the spa or with a new one.
Probable
Debris inside the jet internal
cause #5:
Action:
Remove the internal, inspect for debris, remove debris and re-install. Test
66