Possible Options For Installing The Piping From The Inside Unit To The Outside Unit; Mounting The Installation Plate And Drilling Holes For Piping; Mounting The Installation Plate Of The Indoor Unit - Qlima S(C) 3925 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
6.
POSSIBLE OPTIONS FOR INSTALLING THE PIPING FROM THE INSIDE UNIT TO
THE OUTSIDE UNIT.
The piping can be connected with an outlet to the left or right side of the indoor unit. Remove the
left or right rupture disc as necessary. See Picture 7.
The piping can be connected with an outlet to the right rear or rear left. See Picture 7.
7.

MOUNTING THE INSTALLATION PLATE AND DRILLING HOLES FOR PIPING.

7.1 Mounting the installation plate of the indoor unit.

WARNING
Use a detector before drilling the holes in the wall to detect power cables and piping in the wall
to avoid unnecessary damaging the wall and to avoid dangerous situations.
a.
Position the installation plate  level and on a sufficiently firm wall and leave a free space around
the installation plate. See Picture 8
b.
If the wall is made of bricks, concrete or a similar material, eight holes with a diameter of 5 mm have
to be drilled in the wall. Insert the plugs  for the respective mounting screws  in the wall.
c.
Mount the installation plate  on the wall with eight type "A" screws .
G
NOTE
Mount the installation plate and drill wholes in the wall according the material in which the wall
is build and the respective attachment points on the installation plate. (dimensions are in "mm"
unless indicated otherwise).
Correct mounting of the installation plate
S3925
S3932
Picture 7
Picture 8