More than 30cm
More than 30cm
Fence or barrier
More than 60cm
Figure 5
More than 200cm
W hen determining the location of the exterior unit take into account the possible location of the
interior unit. The interior and exterior units must be connected by pipes and cables.
G
TAKE CARE
For the SC41xx & SC5xxx models: The length of the piping is 4 metres.
For the S41xx & S5xxx models: F or units with a capacity of up to 6.0 kW, the maximum pipe
length between the inside and the outside part is 20 metres. For
units with a capacity > 6.0 kW, the maximum pipe length between
the inside and the outside part is 30 metres.
For units with a capacity of up to 6.0 kW, the maximum difference
in height between the inside and the outside part is 8 metres. For
units with a capacity > 6.0 kW, the maximum difference in height
between the inside and the outside part is 20 metres.
Do not place animals and plants or other obstacles in the path of the air inlet or outlet.
Always install the air conditioner at an easily accessible location.
C onsult and follow local legislation regarding mounting and installation of air conditioner equip-
ment.
I n the case that the installation place is exposed to strong wind such as a seaside, make sure the fan
is operating properly by putting the unit lengthwise along the wall or using a dust or shield plates.
See picture 6.
Incorrect
Incorrect
Strong
Strong
wind
wind
Figure 6
I f the exterior unit is installed on a roofing structure or exterior wall then it can result in bothersome
noise and vibrations.
Ensure that the exterior unit can be attached to a stable substructure.
4
50
50
More than 60cm
Correct
Correct
Barrier
Wall
Strong
Strong
wind
wind
G
ATTENTION
If need suspending installation, the installation bracket should accord with all technical
requirements. The installation wall should be strong enough or actions to reinforce should be
taken. The connection between bracket and wall, bracket and the air conditioner should be firm,
stable and reliable. In case of any doubts or uncertainty do not attempt to install the unit but
have the support calculated and engineered by a skilled engineer.
6.
POSSIBILITIES FOR INSTALLING THE PIPING FROM THE INTERIOR UNIT TO
THE EXTERIOR UNIT.
T he piping can be connected exiting from the left rear or right rear of the interior unit. Remove the
left or right breakout plate. See figure 7.
The piping can be connected exiting from the left rear or right rear. See figure 7.
Cover for the right
piping
Cover for the piping
Right piping
Left piping
Figure 7
Cover for the left
piping
Left back piping
4