10. ELECTRICAL INSTALLATION

Use a separate circuit for the air conditioner. Ensure the circuit is protected by a suitable fuse. See
table below.
The supply voltage must be within 95%~105% of the rated voltage, which is specified on the rating
label.
The supply circuit must be protected by an earth-leakage circuit breaker.
Ensure that the air conditioning is properly grounded.
Connect the cables according the wiring diagram. See Chapter 11.
All wiring has to comply with national and local electrical standards and regulations and has to be
connected by qualified technicians.
Model
≤ 3,5 kW
> 3,5 kW
G
ATTENTION!
The supply voltage must be according the rated voltage of the air conditioning

11. CONNECTING THE POWER CABLES

11.1 Connecting the power cables for the SC 39xx models.

a.
A power cable with a length of 4.0 meter for the electrical connection between indoor and outdoor
unit is supplied with the device and can be found in the packaging of the refrigerant piping (indoor
unit).
b.
This electrical cable is supplied with an electrical push fit coupling.
c.
This electrical cable is supplied with an electrical push fit coupling.
d.
Remove the cover plate of the terminal block of the outdoor unit by unscrewing the screw.
e.
Click the connector of the indoor unit into the connector of the outdoor unit and secure the cable
on the connector block with the mounted cable clamp.
f.
Connect the power cable only when the entire installation of the air conditioner is completed.
Rated input current
Mains
220 - 240V, ~50Hz
220 - 240V, ~50Hz
Cover plate
Picture 17
Diameter power cord
(switch/fuse)
16A
16A slow
2,5 mm
2
2,5 mm
2
4