Conformités Environnementales Et Cem - Etic Telecom XSLAN-1100 Guide Utilisateur

Masquer les pouces Voir aussi pour XSLAN-1100:
Table des Matières

Publicité

3
Conformités environnementales et CEM
Norme
EN61000-4-2
ESD
EN61000-4-3
Radiated
EN61000-4-4
Burst
EN61000-4-5
Surge
EN61000-4-6
RF conducted
EN61000-4-8
Magnetic
EN61000-4-18
Damped wave
Norme
Lightning voltage,
special test protector
Emission test
conducted Disturbance
Radiated emission
DOC_DEV_XSLAN-1100_Guide utilisateur_A
EMC Immunity, EN61000-6-2
critère
Port
B
Enclosure
A
Enclosure
B
SHDSL
Power supply
Ethernet
B
SHDSL
B
Power supply
Ethernet
A
SHDSL
Power supply
Ethernet
A
Enclosure
A
Power supply
B
A
Ethernet
B
SHDSL
EMC Immunity, ITU -T-K21
Critère
Port
A
SHDSL
EMC Emissions, EN61000-6-4
Port
Power supply
SHDSL
Ethernet
Enclosure
Level pass
+/-4kv contact
+/-8kv air discharge
10V/M AM @ 1khz 80Mhz to 3Ghz
+/- 2kv
+/- 2kv
+/- 2kv
+/- 5kv common mode (Normal and Telecom
surge)
+/- 0,5kV common mode
+/- 0,5kV differential mode
+/- 4kv direct shield coupling
10VAM 80% 1khz, 150khz to 80Mhz
30 A/M at 50hz/60hz
+/- 0,5kV differential
+/- 1kV common mode
+/- 1kV common mode
+/- 1kV common mode
K44 Test N°
2.1.2a
+/- 5kV transverse mode (Basic level)
2.1.2b
+/- 5kV port to earth (Basic level)
EN55032, Class A: 150khz to 30Mhz
EN55032, Class A: 30Mhz to 1Ghz
PRESENTATION
Limits
Page 9