5.8.1 Installing the control

the installation of the pump control. The connecting cable of the pump is 3.50 m long. The
installation site of the control has to be selected accordingly. The control has to be installed
in such a way that the cable entries face downward.
!
The control must be installed in such a way that the blue pneumatic hose for the level
control can be laid rising steadily from the lifting unit to the connection at the switch box.
This is the only way to ensure proper functionality of the automatic control.

5.8.2 Attaching the electrical socket

The pump control has a 1.5 m long connecting cable with a CEE-plug or an earth contact
plug. On the part of the building site, an electrical socket with the following data has to be
installed:
CEE socket in case of type
"three-phase current"
• Connected load 400 V/50 Hz
• Right rotating field
• Required fusing on the mains
max. 3 x 16 A, slow-acting
Kompaktboy Single
1.
Transfer the hole pattern onto the wall.
2.
Drill 4 holes, suck away and drive in dowels.
3.
Open the control cover – while doing so, check to
see that no cable connections are loosened.
4.
Using 4 screws, tighten the control.
5.
Put on the control cover and screw down –
while doing so, check to see that no cables are
jammed.
An earth contact socket in case of type
"alternating current"
• Connected load 230 V/50 Hz
• Required fusing on the mains max. 16 A, slow-
acting