9 Technical data

Kompaktboy Single
Motor power P1
Motor power P2
Power supply
Capacitor
Nominal current input
Rated speed
Maximum flow rate
Maximum pumping head
max. medium temperature
Maximum grain size
Gross volume
Weight
Protection class (lifting unit)
Protection class
Motor protection
Required protection
Operating mode
max. contact load fault message
Materials
Collecting tank:
Pump housing:
Motor housing:
Motor shaft:
Seals:
End-face mechanical seal: Carbon / ceramic
Kompaktboy Single
1.1 W 230 V
1.7 kW
1.1 kW
230 V / 50 Hz
50 μF
7.7 A
41 m³/h
8.1 m
42 kg
max.16 A,
slow-acting
PE-LD (polyethylene)
PE–LD
Aluminium
Stainless steel 1.4104
NBR
1.1 D 400 V
1.5 D 400 V
1.4 kW
1.8 kW
1.1 kW
1.5 kW
400 V / 50 Hz
-
2.9 A
3.3 A
1400 U/min
49 m³/h
9.9 m
55° C
50 mm
55 l
43 kg
45 kg
IP 68
F
integrated in the control
max. 3 x 16 A, slow-acting
S 3 - ED 25 %
230 V, 1 A
en English
3.0 D 2P 400 V
3.8 kW
3.0 kW
6.2 A
2800 U/min
35 m³/h
15.0 m
53 kg
81