Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist
company for cooling and air-conditioning or by
®
TROTEC
.
The device runs but forms no condensation:
• Check the condensation drain hose is connected
properly and empty it if necessary.
• Check the condensation drain hose for dirt and
residues. If necessary, clean or replace the con-
densation drain hose.
• Check the room temperature. Check the device's
permissible operating range complies with the
technical data.
• Ensure that the relative humidity complies with the
technical data.
• Check that the selected relative humidity is realis-
tic. The relative humidity in the room must be
above the selected range. Reduce the selected rel-
ative humidity by turning the rotary switch, if nec-
essary.
• Check the air filter is not dirty. If necessary, clean
or replace the air filter.
EN
• From the outside, check the condenser is not dirty
(see "Maintenance" chapter). If your condenser is
dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by TROTEC
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filter are not dirty.
Remove external dirt.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator and the con-
denser for external dirt (see "Maintenance" chap-
ter). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by TROTEC
Your device still does not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC
Operating Manual – Dehumidifier TTK 655 S
®
.
®
.
®
for repairs.