Télécharger Imprimer la page

Shure INTELLIMIX P300 Guide De L'utilisateur page 12

Masquer les pouces Voir aussi pour INTELLIMIX P300:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Mobile Connection (3.5 mm Connector)
Pin Assignments
Tip
Audio Input (Left)
Ring 1
Audio Input (Right )
Ring 2
Ground
Sleeve
Audio Output (To Phone)
Dynamic Range
20 Hz to 20 kHz, A-weighted, typical
Analog-to-Dante
99 dB
Dante-to-Analog
90 dB
Equivalent Input Noise
20 Hz to 20 kHz, A-weighted, input terminated with 20Ω
-95 dBV
Total Harmonic Distortion
@ 1 kHz, 0 dBV Input, 0 dB analog gain
<0.05%
Input Impedance
3.7 kΩ
Input Clipping Level
+4 dBV
Output Impedance
1.4 kΩ
Output Clipping Level
Output terminated with 2.2 kΩ
-20 dBV
Networking
Cable Requirements
Cat 5e or higher (shielded cable recommended)
Important Product Information
The equipment is intended to be used in professional audio applications.
Note: This device is not intended to be connected directly to a public inter-
net network.
EMC conformance to Environment E2: Commercial and Light Industrial.
Testing is based on the use of supplied and recommended cable types.
The use of other than shielded (screened) cable types may degrade EMC
performance.
Changes or modifications not expressly approved by Shure Incorporated
could void your authority to operate this equipment.
Industry Canada ICES-003 Compliance Label: CAN ICES-3 (B)/
NMB-3(B)
Authorized under the verification provision of FCC Part 15B.
Please follow your regional recycling scheme for batteries, packaging, and
electronic waste.
Information to the user
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates uses and can radi-
ate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communi-
cations. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The CE Declaration of Conformity can be obtained from: www.shure.com/
europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Fax: +49-7262-92 49 11 4
Email: info@shure.de
This product meets the Essential Requirements of all relevant European
directives and is eligible for CE marking.
The CE Declaration of Conformity can be obtained from Shure
Incorporated or any of its European representatives. For contact informa-
tion please visit www.shure.com
Accessories
Furnished Accessories
KIT, HARDWARE, P300-IMX 90D33522
BRACKET, HALF RACK UNIT 53A27741
Optional Accessories and Replacement Parts
12
19" rack tray CRT1

Publicité

loading

Ce manuel est également adapté pour:

90d3352253a27741