TEMPERATURE (For 600.219 only)
RANGE
Temperature Range
TEMP.
400ºC ~ 1000ºC
Note: Use "K" type thermocouple probe while measuring
temperature.
DIODE AND AUDIBELE CONTINUITY TEST
Range
OPERATING INSTRUCTION
DC VOLTAGE MEASUREMENT
1)
Connect the red test lead to the "V/
test lead to the "COM" jack.
2)
Set the Function / Range switch to the desired "
the voltage to be measured is not known beforehand, set
the range switch to the highest range and then turn down
range by range until satisfacto ry resolution is obtained.
3)
Connect the test leads to the source or load to be
measured.
4)
Read the voltage value displayed on the LCD along with the
polarity of the red test lead.
0ºC ~ 400ºC
Description
The approx. forward
voltage of the diode
under test will be
displayed on the LCD.
If the resistance of the
circuit under test is less
than 30 Ω, the built-in
buzzer will sound.
RESOLUTION
1ºC
1ºC
Test Condition
The forward DC current
is approx. 1mA, the
reversed DC voltage is
Open circuit voltage
Ω" jack and the black
ACCURACY
±(1.5% rdg+5ºC)
±(1.5% rdg+15ºC)
approx. 2.8V.
approx. 2.8V.
" range
. If