Cable entries, blanking plugs, screw plugs, trumpet-shaped
Warning: The minimum wall thickness
may not be less than 4 mm.
Entry components shall be screwed in tightly
to ensure the specified minimum degree of
protection (see Technical Data, page 3 for
test torques).
Overtightening can impair the degree of
protection.
6.2

Putting into operation

Prior to putting the mounted entry
components into operation, the tests
specified in the individual national regulations
shall be performed.
In addition to this, prior to putting the entries
into operation, the correct mounting shall be
checked in accordance with these operating
and mounting instructions and any other
applicable regulations.
In locations where they are particularly at
risk, the entries shall be safeguarded
against being torn out of the apparatus or
enclosure walls by external mechanical
influences (e.g. by fork lift trucks, by
knocking or similar).
7
Maintenance / Servicing
The valid national regulations for the
servicing / maintenance of electrical
apparatus for use in potentially explosive
atmospheres shall be observed (e.g.
EN 60 079-17).
The necessary intervals between servicing
depend upon the specific application and
shall be stipulated by the operator according
to the respective operating conditions.
As part of the routine testing, above all, parts
on which the explosion protection depends
shall be checked ( e.g. intactness of entry
components and seals).
Pressure screws of cable entries, trumpet-
shaped glands of trumpet-shaped cable
entries shall be checked at regular intervals
to ensure that they are screwed in tightly and,
if necessary, they shall be tightened down.
If, in the course of servicing, it is ascertained,
that repairs are necessary, section 8 of these
operating instructions shall be observed.
12
12
12
12
12
Cooper Crouse-Hinds GmbH
cable glands, reducing glands and drain plugs
8
Repairs / Modifications
Only original COOPER CROUSE-HINDS
parts shall be used for carrying out repairs
that concern the explosion protection.
Repairs that affect the explosion
protection may only be carried out by
COOPER CROUSE-HINDS or by a
qualified electrician in compliance with
the respective national regulations.
(e.g. EN 60 079-19).
Modifications to the entry components are
not permitted.
9
Disposal / Recycling
The respective valid national regulations for
waste disposal shall be observed when
disposing of apparatus.
To facilitate recycling of individual parts, parts
made of moulded plastic bear the marking for
the type of plastic used.