Plaquette signalétique
DC operating volt. range:
DC operating volt. range (MPP):
DC max. input voltage:
DC max. operating current:
DC max. current per string:
AC nom.output voltage:
AC nom.output frequency:
AC max. continuous output current:
AC max. continuous output power:
AC power factor:
Cap 0.8~Ind 0.8
IP class:
IP65
Safety class:
1
Ambient temp: -20° C...+70° C, derating >55° C
SOL2.0-1TR1-G4
EOE45010549
Rev:
XX
Date code:
YYWW
S/N:
LLLMMMXXYYWWZZZZZZ
www.solar-inverter.com
Designed in: Germany
Made in:
production plant
Fig. 5.2:
Plaquette signalétique SOL2.0-1TR1-G4
DC operating volt. range:
DC operating volt. range (MPP):
DC max. input voltage:
DC max. operating current:
DC max. current per string:
AC nom.output voltage:
AC nom.output frequency:
AC max. continuous output current:
AC max. continuous output power:
AC power factor:
Cap 0.8~Ind 0.8
IP class:
IP65
Safety class:
1
Ambient temp: -20° C...+70° C, derating >55° C
SOL3.0-1TR1-G4
EOE46010551
Rev:
XX
Date code:
YYWW
S/N:
LLLMMMXXYYWWZZZZZZ
www.solar-inverter.com
Designed in: Germany
Made in:
production plant
Fig. 5.4:
Plaquette signalétique SOL3.0-1TR1-G4
12
125-600V
150-480V
600V
15A
17A
230V
50Hz
11A
2000VA
5min
125-600V
150-480V
600V
22A
17A
230V
50Hz
15.5A
3000VA
5min
DC operating volt. range:
DC operating volt. range (MPP):
DC max. input voltage:
DC max. operating current:
DC max. current per string:
AC nom.output voltage:
AC nom.output frequency:
AC max. continuous output current:
AC max. continuous output power:
AC power factor:
Cap 0.8~Ind 0.8
IP class:
IP65
Safety class:
1
Ambient temp: -20° C...+70° C, derating >55° C
SOL2.5-1TR1-G4
EOE45010550
Rev:
XX
Date code:
YYWW
S/N:
LLLMMMXXYYWWZZZZZZ
www.solar-inverter.com
Designed in: Germany
Made in:
production plant
Fig. 5.3:
Plaquette signalétique SOL2.5-1TR1-G4
DC operating volt. range:
DC operating volt. range (MPP):
DC max. input voltage:
DC max. operating current:
DC max. current per string:
AC nom.output voltage:
AC nom.output frequency:
AC max. continuous output current:
AC max. continuous output power:
AC power factor:
Cap 0.8~Ind 0.8
IP class:
IP65
Safety class:
1
Ambient temp: -20° C...+70° C, derating >55° C
SOL3.3-1TR1-G4
EOE46010552
Rev:
XX
Date code:
YYWW
S/N:
LLLMMMXXYYWWZZZZZZ
www.solar-inverter.com
Designed in: Germany
Made in:
production plant
Fig. 5.5:
Plaquette signalétique SOL3.3 -1TR1-G4
Manuel d'installation et de fonctionnement pour SOL2.0/2.5/3.0/3.3/3.6/5.0-1TR1-G4
125-600V
150-480V
600V
18.2A
17A
230V
50Hz
15.5A
2500VA
5min
125-600V
150-480V
600V
24A
17A
230V
50Hz
15.5A
3300VA