Télécharger Imprimer la page

Ferm PDM1016 Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
2
Do not change the operating mode
during use.
● Set the switch (6) to position "A" for drilling.
● Set the switch (6) to position "B" for hammer
drilling.
Hints for optimum use
● Clamp the workpiece.
● Firmly hold the machine with both hands.
● Place the drill bit on the workpiece.
● Switch on the machine.
● Do not apply too much pressure on the
machine. Let the machine do the work.
● Switch off the machine and wait for the
machine to come to a complete standstill
before putting the machine down.
CLEAnIng AnD MAInTEnAnCE
4
Before cleaning and maintenance,
always switch off the machine and
remove the mains plug from the mains.
● Regularly clean the housing with a soft cloth.
● Keep the ventilation slots free from dust and
dirt. If necessary, use a soft, moist cloth to
remove dust and dirt from the ventilation slots.
● Regularly clean the chuck and the drill bit to
avoid inaccuracies during use.
Replacing the drill bit (fig. B)
● To remove the drill bit (14), proceed as
described in the section
"Mounting and removing the drill bit".
● To mount the drill bit (14), proceed as
described in the section
"Mounting and removing the drill bit".
Checking and replacing the carbon brushes
(fig. A)
The carbon brushes must be checked regularly.
If the carbon brushes are worn, the machine will
start to run unevenly.
2
Only use the correct type of carbon
brushes.
● Remove the carbon brush covers (11) using
a screwdriver.
● Remove the cover plate from the carbon brush
holder.
● Clean the carbon brushes.
● In case of wear, replace both carbon brushes
at the same time.
● Mount the cover plate to the carbon brush
holder.
● Mount the carbon brush covers (11) using
a screwdriver.
● After mounting the new carbon brushes, let the
machine run at no load for 15 minutes.
wARRAnTy
Consult the enclosed warranty terms.