NOTE: In areas with hard water, reverse polarity systems may require occasional
manual cleaning
Life of EcoSalt electrolytic cells vary substantially from one installation to another due to
variations in operating time, water quality and composition, system and cell
maintenance. Please ensure that when cell replacement is necessary you use the
correct genuine EcoSalt replacement cell to match your system.
Refer to your local EcoSalt dealer for the correct cell for your model.
To clean the EcoSalt In-line Cell
Ensure that the Power Supply is turned off – failure to do so may result in the pool pump
turning on while the Cell is not in place. Disconnect the cell lead and flow switch from the
Cell and remove the Cell from the pool return line by undoing the unions, taking care not
to lose the o-rings.
METHOD
1. Assemble a blanking cap from the supplied plug, o-ring and lock ring.
2. Install the blanking cap onto the end of the Cell opposite the flow switch port.
3. Secure the Cell in a vertical position with the blanking cap at the bottom, to catch any
spills the Cell should be placed in an acid proof container.
4. Add 50mL of HYDROCHLORIC ACID to 500mL of WATER in a suitable sized
container; carefully pour the solution into the open end of the Cell.