5. Alternatively step 4 can be carried out using an approved commercial cell cleaning
solution.
6. As the scale is being dissolved from the plates the solution will foam, when this
foaming action has stopped the Cell is clean and the solution can be returned to the
container for future use or discarded appropriately. NOTE: do not leave the acid
solution in the Cell for more than ! hour.
7. Rinse the Cell out with clean tap water by filling and draining a couple of times, check
that all the scale deposits have been removed, repeat the cleaning process if
necessary.
8. Return the Cell to its position in the pipe work and re-connect the cell lead and flow
switch.
!"#$%&'()*+,&*--&*./-&01&)*0234&52623&*--&)*023&01&*./-7&'()*+,&)2*3&2+2&
83102.0/15&*5-&39::23&;(162,7&'()*+,&.(2*5&0<2&=2((&/5&*&)2((>6250/(*02-&*32*7
EcoSalt Units are also fitted with a Thermal cutout to prevent overheating.
temperature rises too high, power is automatically disconnected. The Unit will resume
operation when it cools down.

DAY TO DAY OPERATION:

Four Prime rules must be observed if your unit is to give the best possible service:
1. STABILISER
FOR OUTDOOR USE
The importance of pool stabiliser cannot be over – emphasised. It is essential in helping
retain chlorine in your pool. Chlorine is rapidly dissipated by sunlight and the use of
stabiliser will reduce this dissipation dramatically.
necessary to run the Unit for up to three times as long!
Stabiliser should be added at the rate of 500 grams for every 10,000 litres of water.
Stabiliser should be maintained at a level of 30 – 50 ppm.
stabilisers, have your pool water analysed at your pool shop to ensure that you do not
add too much.
If you use an ORP controller, the stabiliser should not exceed 15ppm.
FOR INDOOR USE
Stabiliser is NOT needed for indoor pools and as such should not be used.
Please consult your local EcoSalt Dealer for more information on stabilising your
pool.
pH AND TOTAL ALKALINITY:
A correct pH level must be maintained to prevent problems such as black spot, staining,
cloudy water, etc. An incorrect pH level can damage the pool. Correct pH levels are as
follows; Fibreglass – 7.0 to 7.4. Other pools – 7.2 to 7.6. If you allow the pH level to rise
Page 13 of 18
Without stabiliser, it may be
Before adding more
P/N 403185