Temperature Measurement Accuracy ±5.4°F (±3°C)
Humidity Measurement Range
Humidity Measurement Accuracy
Display Type/Size
Droplet Icon Ranges
Auto Power Off
Low Battery Warning Level
Operating Temperature
Dimensions
Weight
Current Consumption
Power Source

MAINTENANCE TIPS

When the
one flashing bar, it's time to replace the 9V battery that powers the meter (although
measurements will remain valid for several hours after the icon first appears).
When the tips of the meter's factory-installed 5mm test pins show signs of wear,
replace them with a pair of 10mm or 15mm pins included in the case.
Remove the battery when storing the meter for an extended period of time.
Do not drop or disassemble the meter or immerse it in water.

WARRANTY INFORMATION

General Tools & Instruments' (General's) MMH800 4-in-1 Pin/Pad RH Moisture Meter is
warranted to the original purchaser to be free from defects in material and workmanship
for a period of one year. Subject to certain restrictions, General will repair or replace this
instrument if, after examination, the company determines it to be defective in material or
workmanship. The warranty period begins on the date of purchase. You are encouraged
to register your product online. General will extend your warranty an additional 60 days if
you register at www.generaltools.com/ProductRegistry.
This warranty does not apply to damages that General determines to be from an
attempted repair by non-authorized personnel or misuse, alterations, normal wear and
tear, or accidental damage. The defective unit must be returned to General Tools &
Instruments or to a General-authorized service center, freight prepaid and insured.
25 to 95%
±5% below 75%RH; ±10% above 75%
99.9 count LCD with 0.56 in. (15mm) high digits
Low/Medium/High moisture: >5%/12%/16% for wood
and paper; >1.5%/17%/20% for building material
After 3 minutes with 0% reading
<7.25V
32° to 122°F (0° to 50°C) @<80% relative humidity
7.13(L) x 2.17(W) x 1.57(H) in. (181 x 55 x 40mm)
4.06 oz. (115g) without battery
<20mADC
9V battery (included)